ELECTRIC AND MAGNETIC FIELDS (EMF)
can affect implanted Medical Devices
• Wearers of Pacemakers and other
Implanted Medical Devices should keep
away.
• Implanted Medical Device wearers should consult their
doctor and the device manufacturer before going near
arc welding, spot welding, gouging, plasma arc cutting or
induction.
NOISE can damage hearing
• Noise from some processes or equipment
can damage hearing.
• Wear approved ear protection if noise level
is high.
FIRE OR EXPLOSION hazard
• Do not install or place unit on, over, or
near combustible surfaces.
• Do not install unit near flammables.
• Do not overload building wiring − be sure power supply
system is properly sized, rated and protected to handle
this unit.
MOVING PARTS can injure.
• Keep away from moving parts such as
fans.
• Keep all doors, panels, covers, and guards
closed and securely in place.
• Have only qualified persons remove doors,
panels, covers, or guards for maintenance
and troubleshooting as necessary.
• Reinstall doors, panels, covers, or guards
when maintenance is finished and before
reconnecting input power.
• Keep away from pinch points such as drive rolls.
FLYING SPARKS can INJURE.
• Wear a face shield to protect eyes and
face.
• Shape tungsten electrode only on grinder
with proper guards in a safe location
wearing proper face, hand and body
protection.
• Sparks can cause fires - keep flammables
away.
READ INSTRUCTIONS.
• Read and follow all labels and the Owner's
Manual carefully before installing,
operating, or servicing unit. Read the
safety information at the beginning of the
manual and in each section.
• Use only genuine replacement parts from the
manufacturer.
• Perform maintenance and service according to the Owner's
Manuals, industry standards, and national, state/provincial and
local codes.
WELDING WIRE can injure
• Do not press gun trigger until instructed to
do so.
• Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.
TRAPPED AIR PRESSURE AND WHIPPING
HOSES can injure
• Release air pressure from tools and
system before servicing, adding or
changing attachments, or opening
compressor oil drain or oil fill cap.
H.F. RADIATION can cause interference
• High-frequency (H.F.) can interfere with
radio navigation, safety services,
computers, and communications equipment.
• Have only qualified persons familiar with electronic
equipment perform this installation.
• The user is responsible for having a qualified electrician
promptly correct any interference problem resulting from
the installation.
• Have the installation regularly checked and maintained.
• If notified by the FCC about interference, stop using the
equipment at once.
• Keep high-frequency source doors and panels tightly
shut, keep spark gaps at correct setting, and use grounding and
shielding to minimize the possibility of interference.
ARC WELDING AND PLASMA CUTTING
can cause interference.
• Electromagnetic energy can interfere
with sensitive electronic equipment such as
computers and computer-driven equipment such
as robots.
• Be sure all equipment in the welding area is
electromagnetically compatible.
• To reduce possible interference, keep cables as short as
possible, close together, and down low, such as on the
floor.
• Locate welding or cutting operation 100 meters from
any sensitive electronic equipment.
• Be sure welding machine or plasma cutter is installed
and grounded according to this manual.
• If interference still occurs, the user must take extra
measures such as moving the welding or cutting
machine, using shielded cables, using line filters, or
shielding the work area.
Page 5

Advertisement

Table of Contents
loading

Table of Contents