Disassembly; Safety Precautions For Disassembly; User Interface Tft Display Assembly Removal - ESAB EMP 215IC Service Manual

Multi process welder
Hide thumbs Also See for EMP 215IC:
Table of Contents

Advertisement

9

DISASSEMBLY

9.01

Safety Precautions for Disassembly

!
WARNING
!
Read and follow safety information in Section 1 before proceeding. Follow
anti static precautions when handling any PCB (Printed Circuit Board).
9.02

User Interface TFT Display Assembly Removal

disassembly. Follow anti static precautions when handling any PCB (Printed Circuit Board).
Unplug the unit before beginning disassembly procedure.
1. Remove eight (8) screws securing the power-side cover and frame to the power supply.
Manual 0463 413 001
WARNING
Buss voltage of 400 VDC will be present on the heatsinks of POWER PCB2
while unit is on. Wait 40 seconds after removing power before handling.
Read and follow safety information in Section 1 before proceeding with
NOTE!
There is a ground wire attached to the inside, bottom of the power-side cover..
Be careful not to pull on the wire when removing the cover.
DISASSEMBLY
ESAB EMS215IC/EMP215IC
8
9-1