1.
Unscrew the appliance's water inlet hose from the tap.
2.
Replace the water filter with a dummy filter.
3.
Pour 5 litres of sanitisation solution into the pressure tank of
the garden pump and close the lid.
4.
Connect the garden pump hose to the water inlet hose of the
appliance and open the tap.
5.
Increase the pressure in the garden pump to max. 5 bar.
6.
Dispense 3 litres of liquid from the water dispenser into the
measuring beaker, and pour it away.
7.
Disconnect the appliance plug from the power supply.
8.
Remove and empty the ice container, then disconnect and
remove the ice maker.
9.
Attach the hose to the water inlet pipe of the ice maker.
10.
Position the measuring beaker and place the hose in it.
11.
Increase the pressure in the garden pump to max. 5 bar again.
12.
Remove the rear cover of the machine room and connect the
grounding conductor of the mains cable (i.e. of the two mains
cables) to the protective conductor terminal of the appliance,
on the left side of the machine room. (view of the rear of the
appliance)
13.
Connect the mains cable to the solenoid valve for the ice
maker and, if applicable, to the safety valve as well.
14.
Insert the current-operated circuit breaker into the socket and
connect with the extension cable (the switch is in the "off"
position). Then insert both mains cables into the distributor.
15.
By switching the distributor on and off, activate the solenoid
valve (solenoid valves) until 1 litre of liquid has poured into the
measuring beaker. Pour away the liquid.
823_58300000113594_ara_en_u – 26.03.2015
16.
Allow the sanitisation solution to take effect for 30 minutes.
Empty and depressurise the garden pump.
17.
Close the tap on the hose of the garden pump and reconnect
the water inlet hose of the appliance to the tap
18.
Position the measuring beaker in the ice maker space and
insert the hose into the measuring beaker. By switching the
distributor on and off, activate the solenoid valves until 5 litres
of liquid has been poured out. Pour away the liquid.
19.
Disconnect the electrical connection by pulling the current-
operated circuit breaker out of the socket. Disconnect the
auxiliary cable connections and return the connections on the
solenoid valve (solenoid valves) to their original state.
20.
Perform a leak test and reinstall the appliance.
21.
Check the effectiveness of the protective measures.
22.
Plug the mains plug of the appliance into the mains.
23.
Draw 5 litres of liquid from the water dispenser and pour it
away.
24.
Insert a new water filter.
25.
Advice to customers:
Throw away any ice produced in the next 24 hours.
Draw fresh water regularly.
Do not switch off the appliance for longer than 24 hours.