Waterflow; Defrosting - Bosch KAN58A40AU Repair Instruction

Hide thumbs Also See for KAN58A40AU:
Table of Contents

Advertisement

5.3

Waterflow

823_58300000113594_ara_en_u – 26.03.2015
5.4

Defrosting

The defrost phase is started when:
- Appliance runtime> 60h
or
-Compressor runtime> 24h
or
-Compressor runtime > 6h and one of criteria below is fulfilled
- operating rate >85% of compressor
- Total door opening time > 2 min.
- An error displayed on displayed (R1, F1, D1, F3, door switch).
Defrosting
Precooling:
Compressor runs until freezer compartment sensor  -27° C or
runtime > 50 min.
1.
Freezer compartment fan is constantly on.
2.
Refrigerator compartment fan is in normal service.
3.
Evaporator heater is off.
Defrosting:
1.
Defrost heater is on.
2.
Both fans and compressor are off.
3.
Defrosting ends when evaporator sensor reaches 13 °C.
4.
If evaporator sensor is defective, process will take 30 min (
error display "d1").
5.
Maximum defrost time is 80 min.
Seite 14 von 50