Parameter
Function
Threshold A
Switching threshold,
input optical power
at input A
Hysteresis
Hysteresis
Amplitude
Amplitude: The
value (in dB relative
to the switching
threshold) above
which the input
optical power must
raise for the switch to
begin the hysteresis
timer before restoring
primary switch
position. Only
applies if Revert is
On.
Hysteresis
Hysteresis Time: The
Time
length of time, in
seconds, that primary
optical power must
remain above the
restore threshold
before switch is
allowed to revert to
primary position.
Only applies if Revert
is On.
Revert
On (1) allows switch
to revert to primary
position after optical
power restored. In
Off (0), switch will
remain in backup
(non-primary)
position.
Primary
Selects the primary
Optical
optical input
Input
Switch
Selects the Normal
Position
switch position
Default
Values
Value
5.0
1.0
60
On(1)
Off(0)
On(1)
PathA(0)
PathA(0)
PathB(1)
PathA(0)
PathA(0)
PathB(1)
Optical Switch Module
Min
Max
Step
-10.0
14.0
0.1
0.5
9.5
0.1
0
600
1
na
na
na
na
na
na
na
na
na
Unit
dBm
dB
sec
na
na
na
55