Self-diagnosis
Symptom/State
Code
E95-312
Communication error between
IC9001 on the IS-102 board and
IC0100 on the DPR-365 board
E95-313
Communication error between
IC0100 on the DPR-365 board and
extension unit
E95-314
Communication error between
IC0100 and IC1200 on the DPR-365
board
E95-315
Communication error between
IC0100 on the DPR-365 and IC0201
on the VIF-58 board
*1
Communication error between
E95-316
IC0100 on the DPR-365 board and
IC0201 on the VIF-58 board
E95-317
Communication error between
IC0100 on the DPR-365 board and
external viewfinder
E95-318
Operation fault of IC0800 on the
VIF-58 board
*1:
Function of this code is not provided in this unit.
PXW-FS7/PXW-FS7K
Correction
IC9001 on the IS-102 board and IC0100 on the DPR-365 board or
the peripheral circuit may be faulty.
Replace the faulty IS-102 board and/or the DPR-365 board.
IC0100 on the DPR-365 board and CN3005 on the IF-1270 board, or
the peripheral circuit may be faulty.
Check the connection between DPR-365 board and IF-1270 board.
And check the connection of the extension connector (CN3005 on the
IF-1270 board).
Replace the faulty DPR-365 board and/or the IF-1270 board.
IC0100 and IC1200 on the DPR-365 board or the peripheral circuit
may be faulty.
Replace the DPR-365 board.
IC0100 on the DPR-365 and IC0201 on the VIF-58 board or the pe-
ripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.
Turn the power off and on again.
IC0100 on the DPR-365 board and CN301 on the VF-93 board or the
peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VF-93 board.
IC0100 on the DPR-365 board and IC0800 on the VIF-58 board or
the peripheral circuit may be faulty.
Replace the faulty DPR-365 board and/or the VIF-58 board.