Flow/Temp/Salinity Sensor Cleaning; Figure 19. Electrolytic Cell Cleaning - Zodiac Pool Systems Nature2 Fusion soft Installation And Operation Manual

Hide thumbs Also See for Nature2 Fusion soft:
Table of Contents

Advertisement

Page 40
8.
Replace the yellow plug after drying and smearing lightly with silicone grease.
9.
Reset valves and switches. Turn pump and sanitizer on.
10. Confi rm chlorine output and settings on the user interface.
6.6

Flow/Temp/Salinity Sensor Cleaning

One (1) time per year or as needed.
occur and will affect the accuracy of the salinity test.
1.
Remove fl ow/temp/salinity sensor from the vessel.
2.
Brush with a mildly abrasive green fi ber household cleaning pad. Contacts should be clean and bright.
3.
Thoroughly rinse the fl ow/temp/salinity sensor with clean tap water. Replace and resume normal operation.
4.
Turn power off and back on in order to recalibrate and reset fl ow/temp/salinity sensor. Reset anytime
fl ow/temp/salinity sensor is unplugged.
Figure 19.
Electrolytic Cell Cleaning
Nature
Fusion Soft Installation and Operation Manual
It is rare but scale formations on the fl ow/temp/salinity sensor sometimes
During electrolytic cell cleaning, only
immerse this portion of the electrode.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Nature2 Fusion soft and is the answer not in the manual?

Table of Contents

Save PDF