Zodiac Pool Systems Jandy Pro Series Levolor Installation And Operation Manual

Zodiac Pool Systems Jandy Pro Series Levolor Installation And Operation Manual

Pool water automatic levelor

Advertisement

Jandy Pro Series Levolor
Electronic Water Leveler
Models K-1100, LX2, K-2300, and LEV110CK/2G
K-1100
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool
equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The
maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that
all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning
notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in
property damage, personal injury, or death. Improper installation and/or operation will void the warranty. Improper
installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage,
or death.
ATTENTION INSTALLER - This manual contains important information about the installation,
operation and safe use of this product. This information should be given to the owner/operator of this
equipment.
®
LX2
INSTALLATION AND
OPERATION MANUAL
K-2300
LEV110CK/2G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Jandy Pro Series Levolor and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zodiac Pool Systems Jandy Pro Series Levolor

  • Page 1 INSTALLATION AND OPERATION MANUAL Jandy Pro Series Levolor ® Electronic Water Leveler Models K-1100, LX2, K-2300, and LEV110CK/2G K-2300 K-1100 LEV110CK/2G WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
  • Page 2 Jandy Pro Series Levolor Electronic Water Leveler ® Page 2 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual...
  • Page 3: Table Of Contents

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 3 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Table of Contents Section 1. Safety Information ...... 4 Section 2. System Description ....5 2.1 Electrical Specifications .......5 2.2 Wiring Diagrams ..........6 Section 3.
  • Page 4: Section 1. Safety Information

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 4 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Section 1. Safety Information IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF PROPERTY DAMAGE OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS...
  • Page 5: Section 2. System Description

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 5 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Section 2. System Description Fill Line Levolor Models K-1100, LEV110CK/2G, and LX2 ® are computer-controlled devices that detect a low water condition and automatically replace the water to a pre- set level.
  • Page 6: Wiring Diagrams

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 6 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Wiring Diagrams This section contains wiring diagrams for the K-1100, K-2300, and LEV110CK/2G, along with detailed views of the factory-direct wiring for 220 VAC and the modified wiring for 110 VAC.
  • Page 7 Jandy Pro Series Levolor Electronic Water Leveler ® Page 7 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual 220 Volt Transformer Operation Line 1 Line 2 Ground Figure 4. K-1100, K-2300, and LEV110CK/2G Factory Wiring for 220 Volt Operation...
  • Page 8 Jandy Pro Series Levolor Electronic Water Leveler ® Page 8 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Front Inside View Back Inside View 24 VAC Connect to Transformer Case Blue Solenoid Transformer Enclosure Connect to Valve Wires...
  • Page 9 Jandy Pro Series Levolor Electronic Water Leveler ® Page 9 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Five (5) Status Lights Red Wires to Filling Valve II Blue Wires to Filling Valve I Black Wire to Power (24 VAC)
  • Page 10: Section 3. Installation Instructions

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 10 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Section 3. Installation Instructions Installing the Control Box NOTE When installing a Levolor on a spa (less than Materials and Tools 300 sq ft of surface area), turn the flow control down to reduce the flow rate of the valve. Installation Materials Supplied for...
  • Page 11: Changing Wiring For 110 Volt Operation

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 11 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Changing Wiring for 110 Volt Connect the 24 VAC water solenoid valve to the 18-gauge solid-core burial cable using the Operation supplied grease-filled wire nuts.
  • Page 12: Installing The Sensor

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 12 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Installing the Sensor NOTE If using a dual style sensor, cut off and discard the sensor you are not planning to use. See Figure 12. Skim Style CAUTION Slip Style Important Safety Instructions. Sensor wires must be continuous and not spliced. Solder all low voltage wire connections when possible and Figure 12. Dual Style Sensor always use grease-filled wire nuts on low voltage connections.
  • Page 13: Installation Diagrams

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 13 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Sensor Probes Anti-siphon Valve House Levolor ® Control Box Irrigation System Check Valve Return Pool Figure 15. Skim (Half-moon) Sensor in Skimmer Installation in Exisiting Pool Installation Diagrams This section shows diagrams of skim (half-moon) style and slip style sensor installations and details.
  • Page 14 Jandy Pro Series Levolor Electronic Water Leveler ® Page 14 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual 9" Deck Lid ½" Conduit Connection 1" PVC Cut 6" Conduit to Sensor PVC Cut to Length Control System at...
  • Page 15 Jandy Pro Series Levolor Electronic Water Leveler ® Page 15 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Levolor Electronic Water Leveler ® 24 VAC 1 ½" to Return Line 110 / 220 VAC Solenoid Valve From City Water Supply 1"...
  • Page 16: Section 4. Operation

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 16 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Section 4. Operation Power Light Sensor Light Fill Light K-1100, LEV110CK/2G, and LX2 The controllers for the K-1100 and LEV110CK/2G (See Figure 22) and the LX2 (See Figure 23) each have three (3) lights.
  • Page 17: Fill Safety Lockout Mode

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 17 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual K-2300 The Sensor II light turns yellow when water is not touching the Sensor II tips. Twenty seconds later, the The controller for the K-2300 has five (5) lights.
  • Page 18: Fill Time Before Lockout

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 18 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Fill Time before Lockout Model K-1100 and LX2: For the K-1100 and LX2 the factory-set Fill time before Jumper Safety Lockout occurs is 20 minutes.
  • Page 19: Section 5. Troubleshooting

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 19 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Section 5. Troubleshooting b. Model K-2300: Disconnect Valve I from the blue wires in the control box and disconnect Valve II from the red wires in the control box.
  • Page 20: Fill Will Not Turn Off

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 20 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Fill Will Not Turn OFF This is a troubleshooting flow chart for the K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will not turn off.
  • Page 21: Fill Will Not Turn On

    Jandy Pro Series Levolor Electronic Water Leveler ® Page 21 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Fill Will Not Turn ON This is a troubleshooting flow chart for models K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will not turn on.
  • Page 22: Section 6. Replacement Parts

    ® contact your nearest Jandy dealer or distributor. See the Jandy website at www.jandy.com for the nearest service center. For further assistance, contact Customer Service at Zodiac Pool Systems, Inc. at (800)-822-7933. NOTE To order the correct part, you need to supply the correct model number and part number. Description Model No. Part No.
  • Page 23 Jandy Pro Series Levolor Electronic Water Leveler ® Page 23 ENGLISH Models K-1100, LX2, K-2300, and LEV110CK/2G Installation and Operation Manual Description Model No. Order Part No. Dual Style (Skimmer or Static Pipe Install) S2046A Dual Style Sensor w/50 ft K-1100, LX2, K-2300 Dual Style Sensor w/100 ft K-1100, LX2, K-2300 S2046C S2046E Dual Style Sensor w/150 ft K-1100, LX2, K-2300 S2046G Dual Style Sensor w/200 ft K-1100, LX2, K-2300...
  • Page 24 UL STD 1563 1.800.822.7933 | www.ZodiacPoolSystems.com CERTIFIED TO CAN/CSA C22.2 NO. 218.1 ©2016 Zodiac Pool Systems, Inc. ZODIAC is a registered trademark of Zodiac International, ® S.A.S.U., used under license. All trademarks referenced herein are the property of their respective owners.

This manual is also suitable for:

K-1100Lx2K-2300Ev110ck/2g

Table of Contents

Save PDF