System Maintenance; Ozone Module Servicing - Del ozone Solar Eclipse Installation & Operation Manual

Ozone plus uv sanitation system
Hide thumbs Also See for Solar Eclipse:
Table of Contents

Advertisement

Solar Eclipse Installation & Operations Manual
FLOW SWITCH RELAY
OZONE
GENERATOR
ASSEMBLY
OZONE GAS
LINE
UV REACTOR
DEL CHECK
VALVE
Figure 4: Solar Eclipse Electro-Mechanical Overview
4A-5. Ozone Module Filters and Orifice
The air entering the Ozone Modules passes
through individual Filters and an Orifice on each
Module inlet. The Filters and Orifices are held in
place by the rubber Filter Cap. (Refer to Figure 5
for a more detailed view)
4A-6. Injector Tube Adapter
This connects the Ozone Gas Line to the Injector
Manifold. When servicing this component, do not
tighten past 10 in-lbs or the component may be
damaged.
4B. System Maintenance
All system maintenance must be performed with
either the UV Access Panel or Enclosure Cover
removed. You will need a size 2 phillips head driver
to remove these components
4B-1. Ozone Module Maintenence
The green Ozone Module Lights on the Ozone
Modules indicate that the Ozone Power Supply is
operating properly. When an indicator light goes
out, replace the corresponding Ozone Module.
4B-2. Ozone Module Replacement Interval
Ozone module life expectancy is 5 years. Even if
the Ozone Module Light(s) are glowing, the Ozone
Module may be producing little or no ozone after
this period of time due to contamination within the
corona discharge ozone chamber.
NOTE: BALLAST LOCATED
ON ENCLOSURE CEILING
NOT SHOWN
FLOW SWITCH
INJECTOR
MANIFOLD
INJECTOR TUBE
ADAPTER
OUTLET
MANIFOLD
4
4B-4. Ozone Gas Line Replacement Interval
Replace the Ozone Gas Line every year or sooner,
if needed. If there is evidence of water leaking
past the Ozone Check Valve toward the Ozone
Modules, shut down the Solar Eclipse immediately
and replace the Ozone Gas Line. If water entered
the Ozone Modules, run the filtration system so air
will be drawn through the Ozone Modules and they
can dry out. Ozone Modules will return to normal
operation when dry.
WARNING: Trace amounts of nitric acid may be
present in the Ozone Gas Line. Wear proper safety
equipment (gloves and eye protection) and avoid
direct contact with any condensation in the line.
4C. Ozone Module Servicing - Refer to
Figure 5
ORIFICE
FILTER
CAP
OZONE
TUBE
FITTING
Figure 5: Ozone Generator Subassembly
4C-1. Opening the Door
The Solar Eclipse may be serviced without
disconnecting any of the plumbing or wiring. Simply
use a slotted screwdriver to turn the door latches
a half turn counter clockwise and open the door.
Reverse the steps to securely close the door.
POWER
CONNECTOR
MODULE POWER
SUPPLY
SPACER
OZONE
MODULE
OZONE
MODULE
TERMINAL
BLOCK
LIGHT