c. Test pool chemistry and adjust pH between 7.4 and 7.6. Adjust
total alkalinity between 80 and 120 ppm.
d. Run pool filtration continuously for 24 hours prior to starting
Ozone Generator.
3B. Initial System Start-Up
a. Turn on pool circulation system.
b. Check for leaks.
c. Verify that ozone is being pulled into the Injector by checking for
bubbles at the return.
If you experience complications, see TROUBLESHOOTING Section
4D, call (800) 676-1335 or visit www.delozone.com for assistance.
3C. System Shut-Down
If the system is to be shut down for an extended period disconnect
the Ozone Generator power cord and disconnect the Ozone Supply
Tubing from the Ozone Generator.
SECTION 4 Maintenance and Service
4A. System Electromechanical Overview
4A-1. Internal Components:
Ozone Module: Each Ozone Module consists of a Power Supply
connected by two high voltage wires to an Ozone Cell.
4B. System Maintenance
4B-1. Ordering Information
To locate a dealer nearest you call 1.800.676.1335 ext. 249 or visit
our web site www.delozone.com
Be prepared with the following information:
• Name
• Address
4B-2. Standard Replacement Parts List
a. EC–AG1U Ozone Module
b. EC–AG2U Ozone Module Assembly
c. Check Valve and Ozone Supply Tubing Assembly 9-0777-01
Item (c.) must be replaced once a year.