Service Manual
Deutz D 2.9 L4 Engine Fault Codes
SPN = Suspect Parameter Number
FMI = Failure Mode Identifier
KWP = Keyword Protocol
SPN
FMI KWP Description
523605
9
300
Timeout Error of
CAN-Receive-Frame TSC1AE;
Traction Control
523606
9
301
Timeout Error of
CAN-Receive-Frame TSC1AR;
Retarder
523612
12
387
Internal software error ECU;
injection cut off
523612
12
612
Internal ECU monitoring
detection reported error
523612
12
613
Internal ECU monitoring
detection reported error
523612
12
614
Internal ECU monitoring
detection reported error
523612
12
615
Internal ECU monitoring
detection reported error
523612
12
616
Internal ECU monitoring
detection reported error
523612
12
617
Internal ECU monitoring
detection reported error
523612
12
618
Internal ECU monitoring
detection reported error
523612
12
619
Internal ECU monitoring
detection reported error
523612
12
620
Internal ECU monitoring
detection reported error
523612
12
621
Internal ECU monitoring
detection reported error
523612
12
623
Internal ECU monitoring
detection reported error
523612
12
624
Internal ECU monitoring
detection reported error
523612
12
625
Internal ECU monitoring
detection reported error
523612
12
627
Internal ECU monitoring
detection reported error
523612
12
628
Internal ECU monitoring
detection reported error
164
SPN
FMI KWP Description
523612
12
523612
12
523612
14
523612
14
523612
14
523613
0
523613
0
523613
0
523613
0
523613
0
523613
0
523613
1
523613
2
523615
3
523615
3
523615
4
523615
4
523615
5
523615
12
523619
2
523698
11
S-80 • S-85 • S-80X
February 2017
637
Internal ECU monitoring
detection reported error
1170 Internal software error ECU
973
Softwarereset CPU SWReset_0
974
Softwarereset CPU SWReset_1
975
Softwarereset CPU SWReset_2
856
Maximum positive deviation of
rail pressure exceeded
(RailMeUn0)
857
Maximum positive deviation of
rail pressure in metering unit
exceeded (RailMeUn1)
858
Railsystem leakage detected
(RailMeUn10)
859
Maximum negative deviation of
rail pressure in metering unit
exceeded (RailMeUn2)
860
Negative deviation of rail
pressure second stage
(RailMeUn22)
862
Maximum rail pressure exceeded
(RailMeUn4)
861
Minimum rail pressure exceeded
(RailMeUn3)
864
Setpoint of metering unit in
overrun mode not plausible
594
Metering unit (Fuel-System);
short circuit to battery highside
596
Metering unit (Fuel-System);
short circuit to battery low side
595
Metering unit (Fuel-System);
short circuit to ground high side
597
Metering Unit (Fuel-System);
short circuit to ground low side
592
Metering unit (Fuel-System);
open load
593
Metering unit (Fuel-System);
powerstage over temperature
488
Physical range check high for
exhaust gas temperature
upstrem (SCR-CAT)
122
Shut off request from supervisory
monitoring function
Part No. 1259369GT