Genie S-80 Service Manual page 109

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

February 2017
5
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to 2
inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to
step 6.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Slowly tighten the
load spring adjustment nut in a clockwise
direction in 10° increments until the overload
indicator light turns off, and the alarm does not
sound. Proceed to step 8.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
6
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to 2
inches. Allow the platform to settle.
Result: The overload indicator lights are off at
the platform and ground controls, and the
alarm does not sound. Slowly loosen the load
spring adjustment nut in a counterclockwise
direction in 10° increments until the overload
indicator light flashes at both the platform and
ground controls, and the alarm sounds.
Proceed to step 7.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: The platform will need to be moved up and
down and allowed to settle between each
adjustment.
Note: There may be a 2 second delay before the
platform overload indicator lights and alarm
responds.
Part No. 1259369GT
7
Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to 2
inches. Allow the platform to settle.
Result: The overload indicator lights are off
and the alarm does not sound. Proceed to
step 8.
Result: The overload indicator lights are
flashing at the platform and ground controls,
and the alarm is sounding. Repeat this
procedure beginning with step 5.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
8
Add an additional 10 lb / 4.5 kg test weight to
the platform.
Result: The overload indicator light is flashing
at both the ground and platform controls, and
the alarm is sounding. Proceed to step 9.
Result: The overload indicator light is off at
both the ground and platform controls, and the
alarm does not sound. Remove the additional
10 lb / 4.5 kg test weight. Repeat this
procedure beginning with step 6.
Note: There may be a 2 second delay before the
platform overload indicator light and alarm
responds.
S-80 • S-85 • S-80X
Platform Components
Service Manual
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-85S-80x

Table of Contents