Test Description - Omega CALIBRE 1666 Technical Manual

13 1/4"
Hide thumbs Also See for CALIBRE 1666:
Table of Contents

Advertisement

Identification
IDENTIFICATION
Rate adjustment
RUN MODE
HALT MODE
BUZZER MODE
CW seconds motor
CW minutes motor
CCW minutes motor
CW minutes and seconds
motor
LAMPE
Even LCD segments
Odd LCD segments
EOL
How to leave the test:
F TEST
OMEGA SA
Test no.

Test description

Test 0
Software identification display.
Displays the current value of the rate correction. This correction is
calculated then saved in the movement during production tests.
This test is also used to modify this value if necessary. Every
Test 1
connection between the battery's + pole and the C+ test point
(respectively C-) accelerates the rate by decrementing the value
(respectively slows down the rate by incrementing the value). This
connection can be made using a conductor tool (tweezers, wire,
etc.):
Test 2
Display all the LCD segments and put μC into
Test 3
Disable the LCD driver and put μC into
Test 4
Trip the BUZZER at a frequency of 2700 Hz.
The seconds motor is moved forward one pitch clockwise every
Test 5
time P1, P2, P3 or P4 is pressed.
The minutes motor is moved forward one pitch clockwise every time
Test 6
P1, P2, P3 or P4 is pressed.
The minutes motor is moved backward one pitch clockwise every
Test 7
time P1, P2, P3 or P4 is pressed.
The seconds motor moves forward at a frequency of 32 Hz and the
Test 8
minutes motor at a frequency of 0.26 Hz (30 second pitches for
one minute pitch).
Test 9
Activates the light.
Displays all the even LCD segments. This test checks whether two
Test A
tracks next to one another are short-circuited.
Displays all the odd LCD segments. This test checks whether two
Test B
tracks next to one another are short-circuited.
Indicates the battery's voltage level.
- Higher than 2.6 V
- Buzzer release
Test C
- Between 2.4 V and 2.6 V
- Buzzer engaged at a frequency of 2000Hz
- Lower than 2.4 V
- Buzzer engaged at a frequency of 2700 Hz
Reset the watch after about four seconds; the watch restarts in
Exit
standard Time mode. To restart in CS test mode (test 0), hold the
crown pressed in.
WORLD SERVICE ORGANIZATION
Specifi c Information for calibre 1666
Test description:
RUN
mode.
HALT
mode.
/7
/7
GT-19-C-069-E - A - 1666

Advertisement

Table of Contents
loading

Table of Contents