7 Service Fixture & Tools
7.1.
When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-PAVC" web-site in
"TSN system", together with Maintenance software.
7.2.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
RFKZ0379
2
RFKZ0446
3
RFKZ0448
4
RFKZ0343
5
RFKZ0446
6
VFK2020
7
VFK1175
Table S1 Extension Cable List
Connection
PS6001 (MAIN) - HDD UNIT
PS6003 (MAIN) - CCD FPC
FP6002 (MAIN) - LENS UNIT
PP6002 (MAIN) - PP6401 (FLASH)
FP6001 (MAIN) - FP6502 (SIDE(R))
PS6101 (SUB) - POWER FPC
FP6402 (MAIN) - REAR CASE FPC
25
Form
40PIN 0.5 B to B
50PIN 0.4 B to B
33PIN 0.3 FFC
30PIN 0.5 B to B
29PIN 0.3 FFC
20PIN 0.5 B to B
16PIN 0.5 FFC