PROBLEMS
POSSIBLES CAUSES
Steam is released from
The seal of the metal plate and/or the
the sides of the lid
edges of the bowl are dirty.
during cooking (leaks).
Wear, cuts and deformation of the seal.
Bowl edges damaged.
The nut for the metal plate was not
tightened enough.
Water flows behind the
The condensation collector is not in
appliance.
position or is overflowing.
The safety valves and/or openings are
obstructed.
The indicator is not
The LED is no longer working or the lid
flashing or does not
is not completely locked.
come on.
The control panel does
The appliance is not connected or is on
not light up.
standby.
The appliance is damaged.
Condensation appears
There is condensation on the lid.
on the indicator.
The metal plate can
The ball cover was not well positioned
not be removed, it is
on the metal plate.
blocked.
SOLUTION
Clean the sides of the bowl and seal using a damp cloth. Do not use any
sharp instruments.
The seal must be changed at least every 3 years. Take your appliance to an
Approved Service Centre.
Take your appliance to an approved service centre.
Fully tighten the nut so the metal plate is correctly positioned. The nut must
be fitted with the flat side facing the metal plate.
Make sure that the condensation collector is properly positioned behind the
appliance and that the flow channel is not blocked. The nut must be fitted
with the flat side facing the metal plate.
Check that the bowl is not too full with food or that foods have been cooked
which expand (see Safety Instructions pages).
Check that the appliance is fully locked. Take your appliance to an Approved
Service Centre if the problem continues.
Check that the power lead is connected both to the appliance and the mains.
Check that the appliance is not on standby by pressing the "OK" button.
Take your appliance to an Approved Service Centre.
Let the appliance dry in fresh air for a few hours.
Unscrew the nut on the metal plate, then press the spring loaded
screw spindle to release the metal plate. Check that the ball cover and
decompression ball are correctly positioned and re-fit if necessary.