3.6 Shortcut of Preset Program

Select a view to be stored (direction of the camera, zoom and focus), then press No. (1 to 240), and then press Pgm, Prst subsequently. The current view will
be stored to the selected preset number if position is empty. If selected preset number is not empty, „PRESET EXISTING" message will be displayed on the
monitor and ask to overwrite.
Example: 1, 0, 1 + Pgm + Prst will store current view as preset No. 101. In this case, focus and Iris mode will be programmed as Auto, dwell time will be set
to 3 sec.

3.7 Tour

(THIRD ITEM OF THE MAIN MENU / SHORTCUT: Tour)
There are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns, Scans or other Tours (second-level). Using second-level Tours, it
can be expanded to over 300 functions in a single Tour. However Tours in second level Tour will be ignored when called by a Tours. The following example
illustrates this concept:
If
Tour1 has Preset1
Preset2
Tour2 has Preset3
Preset4
Tour3 has Preset6
Pattern1 and
Tour4 has Preset7.
Tour1 executes as follows:
Preset1
Preset2
Preset3
Preset1
... (Repeat)
Tour2 executes as follows:
Preset3
Preset4
Preset5
(Tour4 is still valid if called directly from Tour2.)
xxxxx :
16 digits of title for tour label
=== :
blank preset position
SCAN TYPE : Max (Normal)/ Slow V. Scan/ Fast V. Scan
DWELL :
03-99 Sec
003 :
Preset 003 (1~240)
A08 :
Auto Scan 08 (1~8)
P01 :
Pattern 01 (1~4)
T02 :
Tour 02
(1~8)
Follow the steps below to program the Tours:
1. Press Menu to display the main menu on the monitor. Scroll to Tour and push the Joystick to the right to enter the Tour menu. Or just press the Tour key
on the keyboard.
2. Choose an empty location to be programmed by pushing the Joystick up, down, right, or left.
3. To see a stored preset view, use the Joystick to move the cursor to a stored position. By pressing Prst key, the camera will move to the stored Preset view.
Tour2
Tour3 and
Preset5
Tour4 and
Preset4
Preset5
Preset6
Pattern1
Preset7
Preset3 ... Repeat
GUARD TOUR SETUP
TOUR 01
: xxxxxxxxxxxxxxxx
SCAN TYPE : NORMAL
DWELL
: 03
=== === 003 === === === ===
A08 === === === === === ===
=== T02 === 001 === === ===
=== === === T08 === === ===
=== === === === === === ===
=== === === === === === ===
SAVE AND EXIT (ESC TO CANCEL)
PRESS FUNCTION KEY AND ROTATE
JOYSTICK TO SELECT NUMBER.