Sony LDI-D100B Service Manual page 47

Personal lcd display
Table of Contents

Advertisement

QQ
3 7 63 1515 0
[VCOM R Adjustment]
Condition:
Input signal
SVGA 60 Hz: RGB 0.7 Vp-p, 16 Step
Measurement point
MA-324 (H) board CN206 pin qs
Measuring equipment
Digital voltmeter
Adjustment page
F
Adjustment address
75
6.64 ± 0.02 V
Specification value
Connection:
MA-324 (H) Board
CN206 pin qs (COM R)
CN206 pin 9 (GND)
Adjustment Procedure:
(1) Connect a digital voltmeter to the CN206 pin qs on the MA-
324 (H) board.
(2) Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(3) On page: F, address: 75, change data with the PLAY and
STOP buttons and press the PAUSE button to write data so
that the digital voltmeter reading satisfies the specification
value.
Adjustment and Connection Location: MA-324 (H) board
[VCOM L Adjustment]
TE
L 13942296513
Condition:
Input signal
SVGA 60 Hz: RGB 0.7 Vp-p, 16 Step
Measurement point
MA-324 (H) board CN206 pin qf
Measuring equipment
Digital voltmeter
Adjustment page
F
Adjustment address
76
6.64 ± 0.02 V
Specification value
Connection:
MA-324 (H) Board
CN206 pin qf (COM L)
CN206 pin 9 (GND)
Adjustment Procedure:
(1) Connect a digital voltmeter to the CN206 pin qf on the MA-
324 (H) board.
(2) Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(3) On page: F, address: 76, change data with the PLAY and
STOP buttons and press the PAUSE button to write data so
that the digital voltmeter reading satisfies the specification
value.
Adjustment and Connection Location: MA-324 (H) board
www
.
http://www.xiaoyu163.com
Digital Voltmeter
+
(see page 3-30)
Digital Voltmeter
+
(see page 3-30)
x
ao
u163
y
i
3-28
http://www.xiaoyu163.com
2 9
8
[White Balance Adjustment]
Preparation:
Set data: 1F to page: F, address: 7B.
Condition:
Input signal
SVGA 60 Hz: White (50%)
Measurement point
LCD screens
Measuring equipment
Not use (Eye-measurement)
Adjustment page
F
Adjustment address
6B, 6D
Specification value
With no color
Adjustment Procedure:
(1) Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(2) Page: F, address: 6B, 6D
Change data at these two addresses with the PLAY and STOP
buttons and press the PAUSE button to write data so that the
LCD screens turn gray.
POWER SAVING SENSOR
[Power Saving Sensor Adjustment]
Mode
PC
Signal
No signal
Measurement point
Displayed data on the adjusting remote
Measurement equipment commander
Adjustment page
F
Q Q
Adjustment address
57
3
6 7
1 3
1 5
Adjustment Procedure:
(1) Place the reflector (a board pasted kent paper) 6.5 cm away
from sensor.
(2) Set (or confirm) data: 01 to page: 0, address: 01.
(Cancel F page protect)
(3) Set data: 08 to page: F, address 8C.
(Same condition when the POWER SAVE is set to ON)
(4) Set initial value data: 00h to page: F, address: 57.
(5) Set data: 03 to page: 0, address: FF.
(6) See data in page: 3, address: 12.
OK: More than 80.
NG: Below 7F.
If NG, repeat step (4) to (6) after add 08h to the initial value
data of setp (4).
(7) Set data: 00 to page: 0, address: FF.
(8) Set data: 02 to page: F, address: 8C.
Note: It is necessary to input data: 03 to page: 0, address: FF before read-
ing the data in page: 03. Also without input the data: 00 to page: 0,
address: FF, you cannot input any data to page: F after the data in
page: 3 is read.