7. [ADJUST] POSITIONING 1ST AND 2ND MIRROR

[Required equipment] 1
(need modify),Mirror positioning scope.
*Adjustment is performed by turning B58 (2 pcs). The Y-axis (the vertical direction) is adjusted
to a 0 target.
*Front housing must set mirror down position.
① Positioning 1 st mirror : Put the 1
and then adjust the mirror seat so that the adjusting jig touches the mirror without gap.
Tolerance ---- X-axis : ±15'
nd
② Positioning 2
mirror : Attach the mirror positioning scope and the
nd
2
mirror angle adjusting jig to the camera, and then adjust the
mirror angle while looking through the eyepiece lens.
Tolerance ---- X-axis : ±0.3mm
(Refer to below tolerance for positioning scope)
③ After adjustment is done, apply the supper-glue to both B58.
■ Tolerance for 2
nd
(Using with the mirror positioning scope)
2
1
- 2
- 1
- 1
1mm hole
- 2
OK
(Standard)
st
mirror angle (45°) adjusting jig, Mirror angle adjusting jig for 27830
st
mirror angle (45°) adjusting jig on the camera,
Y-axis : ±10'
Y-axis : ±0.1mm
mirror position
Scale
- 2
- 1
1
2
Center of Standard
2
NG: 0.6(Y) or over
1
1
2
- 1
- 2
OK
NG
23
B58
1st mirror
2nd mirror
NG: 0.8(X) or over
NG
: Tolerance of 1 mm hole
(X-axis=±0.8、Y-axis=±0.6)