Panasonic CS-C9PKV Service Manual page 10

Indoor/outdoor units
Hide thumbs Also See for CS-C9PKV:
Table of Contents

Advertisement

Model
Pipe Diameter (Liquid / Gas)
Standard length
Length range (min – max)
I/D & O/D Height different
Additional Gas Amount
Length for Additional Gas
Inner Diameter
Drain Hose
Length
Fin Material
Fin Type
Indoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × L)
Fin Material
Fin Type
Outdoor Heat
Exchanger
Row × Stage × FPI
Size (W × H × L)
Material
Air Filter
Type
Power Supply
Power Supply Cord
Thermostat
Protection Device
Indoor Operation Range
Outdoor Operation Range
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
Specifications are subjected to change without prior notice for further improvement.
2.
Indoor
Outdoor
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
mm
mm
A
Maximum °C
Minimum °C
Maximum °C
Minimum °C
CS-C28PKV
CU-C28PKV
6.35 (1/4) / 15.88 (5/8)
5.0 (16.4)
3 (9.8) ~ 30 (98.4)
20 (65.6)
30 (0.3)
7.5 (24.6)
16.7
650
Pre Coat
Slit Fin
2 × 15 × 21
810 × 315 × 25.4
Blue Coated
Corrugated Fin
2 × 28 × 17
44 × 711.2 × 787.4:821.4
Polypropelene
One-touch
Outdoor
20
Mechanical
Dry Bulb
32
16
43
16
10
Wet Bulb
23
11
26
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents