High Limit Thermostat
For both the electric and gas
models, the high limit thermostat
opens at 315°F and will
automatically reset at 250°F.
To remove the high limit thermostat:
1. Remove the drum.
2. Disconnect the 2 wires from the high limit thermostat.
3. Remove the Phillips-head screw that attaches the high limit thermostat to
the heater assembly or diffuser.
4. Slide the thermostat from the heater assembly or diffuser.
Copyright 2011