Tee Supported Installations - DuraVent duraplus Installation Instructions Manual

All-fuel chimney system
Table of Contents

Advertisement

4. Complete Installation: Refer to Steps 8,
and 9, in the Ceiling Supported Installation
section, to complete the Roof-Supported
installation.
TEE-SUPPORTED INSTALLATIONS
Tee-Supported installations are used when
passing through a wall to an outside chimney.
The required parts and general configuration
are as shown in Figures 23, and 24.
1. Place Appliance: Position the appliance
according to the manufacturer's instructions.
2. Cut and Frame Opening: Cut
14-1/4 inch diameter holes in the inner and
outer walls. The center of these holes should
be aligned with the center of the stove's flue
outlet collar. For new construction, prior to
sheetrock or other covering of the wall studs is
applied, frame a square opening between the
studs, as specified in Table 2. ( Figure 25).
Should it be necessary to go through concrete,
masonry, or cinder-block, a 14-1/4 inch
WARNING:
VENTILATED
FLASHING MUST
BE USED WITH
ENCLOSURES.
16
ALLOW 1/2 INCH AIR
SPACE BETWEEN BASE
OF FLASHING OR COVER
AND ENCLOSURE
FRAMING.
FRAMED
ExTERIOR
ENCLOSURE
TYPICAL
THRU-THE-WALL
TEE- SUPPORTED
INSTALLATION
ACCESS DOOR
FOR CLEANING
Figure 23
PIPE SECTION
6-INCH OR 9-INCH
SDP-P
WALL THIMBLE
SDP-WT
TEE SUPPORT
SDP-TS
PIPE
SDP-P
TEE
SDP-T
TEE CAP
COMPONENT OF
SDP-T
TEE CAP
(COMPONENT OF
SDP-T)
Figure 24
14 1/2"
14 1/2"
Figure 25
5/16 x 3" LAG
SCREWS
(6 REq) NOT
FURNISHED
REMOVABLE
TRAY
(COMPONENT
OF SDP-TS)