5
Secure the connection cable onto the control board with the holder (clamper).
•
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
•
Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires for safety reason.
11.1.8
Wire Stripping And Connecting Requirement
11.1.8.1
Cutting and flaring the piping
1
Please cut using pipe cutter and then remove the burrs.
2
Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping
end down to avoid the metal powder entering the pipe.
3
Please make flare after inserting the flare nut onto the copper pipes.