RUN MODE
Upon first entering the Run Mode, the system will attempt to light the grill for a maximum of 30 minutes. During
this 30 minutes, the auger is run at a 15% duty cycle (on for 1 second, off for 6.7 seconds), the igniter is turned on
full, and the fan is turned on full. If after 30 minutes of this operation the measured Grill Probe temperature has
not exceeded 150°F, the system will enter the Error mode and display the error code for failure to start (
). If
the Grill Probe temperature exceeds 150°F, the system will turn off the igniter and begin to control the Grill Probe
temperature to the setpoint target.
GRILL PROBE SETPOINT DISPLAY STATE
The seven segment display will show the Grill Probe Setpoint temperature by default:
In the Grill Probe Setpoint display state, the Grill Probe setpoint can be adjusted with the Temp Up and Down
buttons. The Grill Probe setpoint defaults to 350°F, but can be adjusted between 150°F and 550°F in 5°F
increments.
Note – Grill will default to last known set point after first start up. Set Point will reset every time the grill is
unplugged to the default value.
GRILL PROBE ACTUAL DISPLAY STATE
Press the Temp Display button to toggle to the Actual measured temperature of the Grill on the display:
In this state, if the Temp Up or Down buttons are pressed, the display will revert to the Grill Probe Setpoint Display
state.
If a Meat Probe is detected, pressing the Probe Display button will change the display state to the Meat Probe.
pg. 20