Haier HCR2250AES Installation Instructions Manual page 23

24" electric free-standing range
Hide thumbs Also See for HCR2250AES:
Table of Contents

Advertisement

Available languages

Available languages

NOTE: Allow enough slack to connect the wires to the terminal block.
a
b
c
a
Jumper Wire
b
Terminal Block
c
Ground Screw
d
Power Cord Wires
5. Remove the green jumper wire from under the ground screw and replace with
the green wire from the conduit and tighten ground screw.
6. Loop the green jumper wire removed from the ground screw back onto its end
that is fastened to the center post of the terminal block.
7. Use 3/8" (1.0 cm) nut driver to connect the neutral (white) wire to the center
terminal block post with one of the 10-32 hex nuts.
8. Using 10-32 hex nuts, connect the red and black wires from the conduit to the
outer posts of the terminal block with the corresponding red and black wires
from the range.
9. Tighten the hex nuts completely, and then verify the connection.
10. Position the back panel against the back of the range, but do not fasten.
11. Gently, pull the excess conduit to the outside.
e
Strain Relief Nut
f
UL Listed Strain Relief
g
Back Panel
d
e
f
g
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hcr2250acs

Table of Contents