Pump Head Tube Replacement Instructions - Pentair INTELLIpH Installation And User Manual

Acid dispenser system
Table of Contents

Advertisement

10
Pump Head Tube Replacement Instruction (for units built after 8/2014)
Before starting the tube replacement procedure, read all safety precautions on page i and ii.
IMPORTANT! Replace the IntellipH pump head tube (P/N 522480) once a season
(yearly). For units built before 8/2014, replace the whole pump head (P/N 521514)
every season.
To remove the tube from the pump:
1.
Pull the lock lever tab 180° from left to right to unlock the cover latch. See Figure 1.
2.
Push up on the raised edge of the front cover and slide cover off. See Figure 2.
3.
Release the fittings from the slots to remove the tube. See Figure 3.
4.
Disconnect the suction and discharge connections from pump head.
5.
Remove the roller assembly.
6.
Use non-citrus all-purpose cleaner to clean residue from pump head housing,
roller, and cover.
7.
Check cover for cracks. Replace if cracked (P/N 522386).
8.
Ensure rollers spin freely.
9.
Note: if the rollers are seized or visibly worn, replace roller assembly.
10. Re-install roller assembly.
Pull lock lever
tab from left
to right side to
unlock
INTELLIPH
ACID DISPENSER Installation and User's Guide
®
Figure 1.
Slide tube
out of slot
Discharge
Push up on
raised edge
of cover to
slide cover
off.
Suction
Slots
Figure 2.
Slide tube
out of slot
Figure 3.

Advertisement

Table of Contents