Operating Mode; Enter Button; Menu Button; Add Acid Manually - Pentair INTELLIpH Installation And User Manual

Acid dispenser system
Table of Contents

Advertisement

Operating Mode

In normal operating mode, the display will alternate between "IntellipH pH CONTROLLER"
and "MIN UNTIL NEXT DISPENSE". Each message is displayed a few seconds before
rotating to the next message. The "XX" is a minute countdown timer that counts down from
60 to 00.

ENTER button

If the ENTER button is pressed during normal display mode, the system information is
displayed for four seconds:
IntelliChlor
cell model

Menu Button

Press the MENU button to display the system choices. Use the MORE or LESS button to
scroll through each choice. Press the ENTER button to select that choice. Pressing the
MENU button will exit that menu.

Add Acid Manually

When this selection is displayed, press the ENTER key to begin dispensing acid. The
pump will turn on for 60 seconds and a countdown timer will be displayed along with a
running total of acid being dispensed. Approximately 4 oz. of acid will be dispensed.
If the acid hose has air bubbles, the amount pumped will be slightly less than amount
displayed on the LCD screen. Press the ENTER key at any time to exit this mode. If the
ENTER key is not depressed, the system will return to normal operation after the 60
seconds has elapsed.
IntellipH
pH CONTROLLER
IntelliChlor
output selection
SCG
®
IC40 60% V2.11
IpH SET TO 50%
Dispense Amount
INTELLIPH
XX MIN UNTIL
NEXT DISPENSE
SCG
®
0-100%
0-100%
ACID DISPENSER Installation and User's Guide
®
Software version of the
IntellipH
Controller
®