Acid dispenser system
Table of Contents

Advertisement

Pump Head Tube Replacement Instruction
I
nstall the New Tube
1.
To install new tube, insert one fitting into slot, pull tube around the center of
the roller assembly and insert second fitting into the other slot. See Figure 4.
2.
Align tube housing cover with track and slide over tube to seat the cover in
place. See Figure 5.
3.
To lock cover in place, push lock lever down on the cover while turning the
vertical tab180° from right to left. See Figure 6.
4.
Reconnect the suction and discharge lines.
5.
Prime pump.
6.
Rinse the area with water.
Insert tube
into slot
Discharge
Suction
Slots
INTELLIPH
(Continued)
Push down on top of
cover to seat in place
Tube
Insert tube
into slot
Figure 4.
Figure 6.
Push lock lever
tab from right to
left side to lock in
place