Floating Load Configuration; Input Connection Diagram - PiezoDrive PD32 Manual

32 channel piezo driver multi-channel high voltage amplifier
Hide thumbs Also See for PD32:
Table of Contents

Advertisement

4.2 Floating load configuration
The floating load configuration is useful for achieving higher peak‐to‐peak voltage swings. The connection 
diagram is illustrated below. Do not connect either of these signals to ground, for example, an oscilloscope 
probe.
 
 
The desired output voltage range can be selected from the following table.  
 
5 Input Connection Diagram
The front panel input connector is an industry standard DB37 Female Connector (TE 1658612‐1). Any Male 
DB37 cable plug is compatible. The connection diagram is illustrated below.  
 
 
 
 
In1
30
Min Voltage  Max Voltage 
‐140 
‐100 
Signals 
Analog Inputs 1 to 32 
Digital disable command 
Overload indicator 
Out1+
+
Piezo 1
Out1‐
Order Code 
+140 
PD32‐140/140 
+100 
PD32‐100/100 
Input Connector
Pins 1 to 32 
Pin 36 
Pin 37 
Notes 
+/‐ 10V max 
3.3V or 5V logic 
5V logic 
 