4.2 Floating load configuration
The floating load configuration is useful for achieving higher peak‐to‐peak voltage swings. The connection
diagram is illustrated below. Do not connect either of these signals to ground, for example, an oscilloscope
probe.
The desired output voltage range can be selected from the following table.
5 Input Connection Diagram
The front panel input connector is an industry standard DB37 Female Connector (TE 1658612‐1). Any Male
DB37 cable plug is compatible. The connection diagram is illustrated below.
In1
30
Min Voltage Max Voltage
‐140
‐100
Signals
Analog Inputs 1 to 32
Digital disable command
Overload indicator
Out1+
+
Piezo 1
Out1‐
Order Code
+140
PD32‐140/140
+100
PD32‐100/100
Input Connector
Pins 1 to 32
Pin 36
Pin 37
Notes
+/‐ 10V max
3.3V or 5V logic
5V logic