Trane 20-80 ton water-cooled air conditioners 20-60 ton air-cooled air conditioners remote air-cooled condensers manual pkg-prc002-en intellipak signature series (101 pages)
This service manual covers the installation, Motor • Coil assembly is tested over 25 kg/cm operation and maintenance of the Trane • Motor is of permanent split capacitor type Bar) and are recommended for operation HFCF chilled water Fan Coil. It should be...
Page 5
X =Stainless Steel w/ 25mm Non-flammable Close Cell Insulation Y =Stainless Steel w/ 25mm Non-flammable Close Cell Insulation & Extended 200mm Z =Stainless Steel w/ 25mm Non-flammable Close Cell Insulation & Extended 310mm Digit 16 : Trane Digital Grille(TDG) N =None A =with Remote Controller Only B =with LCD Thermostat Only C =with LCD Thermostat &...
2. Put the upper W3/8 nuts and W3/8 lock units: washers on suspension rods to prevent Trane HFCF Fan Coil units are packaged in 1. Allow adequate space for the unit and free unit from upward tilting during unit individual cartons for maximum protection air or service clearances reference Figure 2.
Attach the drain line to the drain connection position before servicing the unit. Failure with tape-sealant to prevent leakage. A drain to do so may result in personal injury or line pitch with a minimum slope of 1:50 is death from electrical shock. recommended. HFCF-SVX01A-EN...
HFCF-SVX01A- Dimension Data and Weights Figure 4: HFCF Without Return Plenum Figure 5: HFCF With Bottom Plenum Control B ox Motor Centrifugal Hange r Holes(Qty.6) Se e View A Hanger Holes(Qty.4) See V iew A R etu rn Pl e num Ce ntrif ugal Fan Moto r Unit: mm...
• Owner-operator is instructed on unit operation. CAUTION: Use only copper conductors for wiring connections. Unit terminals are not designed to accept other types of wiring. Aluminum or other conductors may cause overheating and unit damage. HFCF-SVX01A-EN...
Coil drainage When the coil need to maintenance, or protected the water frozen in the low temperature condition, you should turn the water vent for drainage the water in the coil. The operator manner just like as the air vent. HFCF-SVX01A-EN...
8. After replacing the fan housing or fan wheel, the fan board, if applicable, as shown on treatment if any, is advisable. The Trane follow the opposite procedures to re-install. Figure 8-2. Company assumes no liability for the 6.
Trane has operation training After replacing the motor, make sure the fan available through the local Trane Sales Office. wheel is balanced and centered in the fan This training could be provided at housing and not rubbing on either side.
Page 16
Date March 2008 Supersedes www.trane.com Trane has a policy of continuous product and product data improvement and reserves the right to change design For more information, contact you local Trane office or e-mail and specifications without notice. us at comfort@trane.com...