Follett MCD425A/W Operation And Service Manual page 19

Table of Contents

Advertisement

Normal operation – Stage 8
When the dwell time of 20 minutes has expired, the TIME DELAY LED goes off . If 5 seconds of ice has been
dispensed and the SLEEP CYCLE LED (Symphony Plus only) is off, the ice machine will go through the normal
start-up sequence when the bin level control signals the control board for ice .
Start
Capacitor
Relay
OR
YELLOW
A B C D
Water Sensors
Quiet Night/Sleep cycle (Symphony Plus only)
The board monitors ice dispensing through a line voltage input to P15 . If the ice dispense has not be initiated for
more than 5 seconds during the 20 minute time delay, the SLEEP CYCLE LED comes on . The machine will stay
off for 12 hours unless 5 seconds of dispensing is seen . After 12 hours, the SLEEP CYCLE LED goes out and the
ice making will resume if the bin thermostat is closed . The sleep cycle dispense duration is adjustable using the
DIP switches on the control board .
T.O.L.
R
S
C
Compressor
2
1
RED
Start
Relay
5
Compressor
Electrical Box
WHITE
Drain
Fill
4
Valve
Valve
3
2
BLACK
R
S
C
Gearmotor
Drain Clog Sensor
MCD425A/W, R425A/W, MFD425A/W, P425A/W Ice Machines
Fan
WHITE
N
N
L1
BLACK
L1
RED
P6
P21
P20
BROWN
P19
BLACK
P3
P22
BLUE
P4
AUGER
Bin T-Stat
High
Pressure
Switch
POWER
P15
LOW BIN
MAKING ICE
SLEEP CYCLE
HI PRS
TIME DELAY
LOW WATER
1 2 3 4 5 6 7 8
MAINTENANCE
RESET
SERVICE
HI AMPS
WATER LEVELS
HI PRESSURE
DRAIN CLOG
P11
BIN
CLEANER FULL
Clean Switch
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfd425a/wR425a/wP425a/w

Table of Contents