MINIFLEX
®
PORTABLE WELDING FUME EXTRACTOR

GENERAL DESCRIPTION

The MINIFLEX
®
is a portable, high vacuum welding fume extractor
designed for the removal and filtration of welding fumes from light
duty welding applications. Its compact size permits the MINIFLEX to
be used in confined spaces and other locations that are not
accessible with other welding fume extractors.
The convenient automatic start/stop function can extend the life of the
motor brushes and reduces energy consumption. (Note: welding
current must be at least 50 amps to activate sensor). The optional
wall mounting bracket allows the unit to be mounted to a wall, freeing
up floor space.
The MINIFLEX can be completely disassembled in a matter of minutes
for cleaning and maintenance.
Unit includes:
• 8 ft. (2.5 m) extraction hose with 1-3/4 in. (45mm) I.D.
hose adapter.
• Two sets of seals and carbon brushes.
use with nozzles and  hoses
The MINIFLEX is not supplied with a nozzle. Nozzles and extra hoses
can be ordered separately. The recommended nozzles and hoses are:
• Extraction Nozzles: EN 20 or 40 (K2389-5, K2389-6)
• Nozzle Kits: NKT or NKC (K2389-3, K2389-4)
• Fume Exhaust Guns
• Extraction Hoses:
- 8 ft. (2.5m) long x 1-3/4 in. (45mm) I.D. (K2389-9)
- 16 ft. (5m) long x 1-3/4 in. (45mm) I.D. (K2389-8)
• Hose-to-Hose Adapter (K2389-10)
• Hose Connection Outlet (K2389-2)
See Accessories section for more information.
Note: Recommended maximum hose length is 24 ft. (7.5m) on extraction side
of unit. Consult lincoln electric automation department at
1.888.935.3878 before using any other size or length of hose.
TECHNICAL
SPECIFICATIONS
INPUT VOLTAGE
RATED CURRENT DRAW
POWER RATING
OPERATING SOUND LEVEL
FILTER TYPE
STAGE ONE
STAGE TWO
STAGE THREE
STAGE THREE SURFACE AREA
STAGE FOUR (OPTIONAL)
STAGE FIVE
UNIT EFFICIENCY
AMBIENT CONDITIONS
MINIMUM TEMPERATURE
MAXIMUM TEMPERATURE
MAXIMUM RELATIVE HUMIDITY
OPERATING CAPACITY
EXTRACTOR TYPE
AIRFLOW RATE
PHYSICAL DIMENSIONS
HEIGHT
DIAMETER
INLET/OUTLET OUTER DIAMETER
WEIGHT
Particle size: 0.3 µm. Testing method: Flat-sheet tested according to
(1)
EN 1822-3:2009 @ 190 m
/h with test aerosol generated according to
3
EN 1822-2:2009.
Meets Integral Collection Efficiency Value for Filter Class E12 per
(2)
EN 1822-1:2009.
NOTE: Technical specifications are subject to change without prior notice.
Specifications and guarantees a re valid only when specified
replacement parts and filters are used.
9

INSTALLATION

GENERAL
115V, 1Ph, 60Hz
230V, 1Ph, 60Hz
115V - 14.6A
230V - 8.8A
2.4 HP (1.2 HP PER MOTOR)
< 70 DB(A)
SEPARATE MESH SCREEN
PRE-FILTER
INTEGRATED MESH/SCREEN
PRE-SEPARATOR
LONGLIFE-H™ PRETREATED
CELLULOSE FILTER
130 SQ. FT. (12 M
ACTIVATED CARBON FILTER
HEPA (HIGH EFFICIENCY
PARTICULATE AIR) FILTER
99.7% @ 0.3 m
40ºF (5ºC)
104ºF (40ºC)
80%
HIGH VACUUM, LOW VOLUME
LOW MODE: 94 CFM (160 M
HIGH MODE: 135 CFM (230 M
29.0" (730 MM)
16.5" (420 MM)
1-3/4" (45 MM)
38 LBS. (17 KG)
2
)
(2)
(1)
3
/HR)
3
/HR)

Hide quick links: