Trouble-Shooting
Problem:
SHAVER
Shaver does not start
when pressing the
start button.
Shaver does not
charge completely
and keeps blinking.
Charging does not
start when connected
to power socket or
put in Clean&Charge
Station.
Unpleasant smell
from the shaver head.
Battery performance
dropped significantly.
Shaving performance
dropped significantly.
Shaver turns off with
fully charged battery.
Shaver head is
damp.
CLEAN&CHARGE STATION
Cleaning does not
start when pressing
the start button.
Increased
consumption of
cleaning fluid.
10
Possible reason:
1. Travel lock is activated.
2. Wet&dry models
9095cc w&d/9040s.
This appliance can only be
operated cordlessly.
Ambient temperature is out of
valid range.
1. Shaver is not placed properly
in the Clean&Charge Station.
2. Sometimes charging could
start delayed (e.g. after long
storage).
3. Ambient temperature is out
of valid range.
4. Special cord set is not
plugged in properly.
1. Shaver head is cleaned with
water.
2. Cleaning cartridge is in use
for more than 8 weeks.
1. Shaver head is regularly
cleaned with water but not
lubricated.
2. Foil and cutter are worn
which requires more power
for each shave.
1. Shaving system is clogged.
2. Foil and cutter are worn.
Foil and cutter are worn which
requires more power than
the motor can deliver. The
appliance turns off.
1. Drain of the Clean&Charge
Station is clogged.
2. Cleaning cartridge has been
used for quite a while.
1. Shaver is not placed properly
in the Clean&Charge Station.
2. Cleaning cartridge does not
contain enough cleaning fluid
(level indicator blinks red).
3. Appliance is in stand-by
mode.
Drain of the Clean&Charge
Station is clogged.
Remedy:
1. Press the on/off switch for 3 seconds to unlock
the shaver.
2. Unplug the shaver.
Recommended ambient temperature for charging is
5 °C to 35 °C.
1. Contacts of shaver need to align with contacts in
the Clean&Charge Station.
2. Wait a few minutes, if charging will start auto-
matically.
3. Recommended ambient temperature for charging
is 5 °C to 35 °C.
4. Special cord set needs to snap into place.
1. When cleaning the shaver head with water only
use hot water and from time to time some liquid
soap (without abrasive substances). Remove Foil
& Cutter cassette to let it dry.
2. Change cleaning cartridge at least every 8 weeks.
1. If the shaver is regularly cleaned with water, apply
a drop of light machine oil on top of the foil once
a week for lubrication.
2. Replace Foil & Cutter cassette.
1. Soak the Foil & Cutter cassette in hot water with
a drop of dish liquid. Afterwards rinse it properly
and tap it out. Once dry apply a drop of light
machine oil on the foil.
2. Replace Foil & Cutter cassette.
– Replace Foil & Cutter cassette.
– Regularly oil the shaving system, especially when
cleaning with water only.
1. Clean the drain with a wooden toothpick.
2. The alcohol proportion has decreased while the
oil proportion has increased. Remove residue
with a cloth.
1. Insert shaver into the Clean&Charge Station
(contacts of the shaver need to align with
contacts in the station).
2. Insert new cleaning cartridge.
3. Press start button again.
– Clean the drain with a wooden toothpick.
– Regularly wipe the tub clean.