6.12

Default SSMB

The transmitted SSMB timing marker value can be configured for all output ports when
in equipment Freerun mode, or when timing marker operation is disabled, as
described in Section 6.3. Any of the SSMB codes in Table 6-6 may be configured.

Table 6-6: SSMB Timing Marker from MSOH S1 Byte (Defaults)

Serial
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Note:
6.13

SSMB Code to Quality Level Assignment

Quality levels between 1 and 16 may be configured against each SSMB code. One (1)
is the highest quality level. Only the codes assigned by the operator may be used
when performing the configuration described in Sections 6.9, 6.11.1.
Note:
6.14

SASE Mode

The equipment can be configured in Stand Alone Synchronisation Equipment mode
(SASE) or one of the Enhanced SASE Modes (ESM). An external SASE regenerator
is used to clean the timing signal on the T4 output before it is fed back into the T3
input.
221 02-ZAP 701 25/1 Rev C 2006-08-04
03PHB00004AAV-CUA
SSMB code bits:
5 6 7 8
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
Default: - 1011 (G.813).
Defaults: - as Table 6-6.
Options:
Technical Product Description
Quality
16
Quality unknown (treated as Undefined)
16
Undefined
1
Traceable to G.811
16
Undefined
2
Traceable to G.812 transit clock
16
Undefined
16
Undefined
16
Undefined
3
Traceable to G.812 local clock
16
Undefined
16
Undefined
4
Traceable to G.813 clock
16
Undefined
16
Undefined
16
Undefined
16
Not to be used for synchronisation