TROUBLESHOOTING

4-1-4. Display function of Load condition

① Freezer + Control Test Key are pressed simultaneously for 6 seconds, ALL ON/OFF will blink with
0.5interval for 4 seconds.
② If take the finger off from above keys and press Fridge, load condition mode will be started.
1) If Freezer + Control Test Key are pressed simultaneously for 6 seconds during normal operation, the
temperature setting display of fresh food and freezer compartments will blink ALL ON/OFF with 0.5 for 4
seconds.
2) At this moment, If Fridge Key after Freezer + Control Test Key is pressed, load condition display mode will be
returned with alarm. At LED all on state, only load condition display will blink ON/OFF with 0.5 seconds
interval.
3) Load condition display mode shows the load that micom signal is outputting.
However, It means that micom signal is outputting, it does not mean whether load is operating or not. That is to
say that though load operation is displayed, load could not be operated by actual load error or PCB relay
error etc. (This function would be applied at A/S.)
4) Load condition display function will maintain for 30 seconds and then normal condition will be returned
automatically.
5) Load condition display is as below.
R-1
R-10
F-1
F-10