5. INDOOR FAN CONTROL

(1).Fan speed
( Table 5 : Indoor Fan Speed )
Operation mode
Heating
Cooling
Fan
Dry
Operat ion mode
Heating
Cooling
Fan
Dry
Operation mode
Heatin g
Cooling
Fan
Dry
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor
fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
AS*9LSACW
Air flow mode
Speed (rpm)
Hi
1420
Me+
1370
Me
1200
Lo
1000
Quiet
900
Cool air
850
prevention
S-Lo
480
Hi
1350
Me
1150
Lo
950
Quiet
740
740
AS*9LSBCW
Air flow mode
Speed (rpm)
Hi
1390
Me+
1350
Me
1200
Lo
1000
Quiet
760
Cool air
760
prevention
S-Lo
480
Hi
1300
Me
1120
Lo
950
Quiet
700
700
AS*14LSBCW
Air flow mode
Speed (rpm)
Hi
1480
Me+
1420
Me
1300
Lo
1110
Quiet
950
Cool air
850
prevention
S-Lo
480
Hi
1480
Me
1260
Lo
1040
Quiet
850
850
Operation mod e
Heating
Cooling
Fan
Dry
Operation mode
Heating
Cooling
Fan
Dry
Operation mode
Heating
Cooling
Fan
Dry
05-05
AS*12LSACW
Air flow mode
Speed (rpm)
Hi
1470
Me+
1420
Me
1290
Lo
1110
Quiet
980
Cool air
850
prevention
S-Lo
480
Hi
1400
Me
1200
Lo
1000
Quiet
820
820
AS*12LSBCW
Air flow mode
Speed (rpm)
Hi
1440
Me+
1350
Me
1200
Lo
1000
Quiet
760
Cool air
760
prevention
S-Lo
480
Hi
1370
Me
1150
Lo
950
Quiet
700
700
AS*18LSBCW
Air flow mode
Speed (rpm)
Hi
1480
Me+
1420
Me
1300
Lo
1110
Quiet
Cool air
prevention
S-Lo
Hi
1480
Me
1260
Lo
1040
Quiet
950
850
480
850