Fujitsu AS*9LSACW Service Instructions Manual page 55

Wall mounted type inverter
Table of Contents

Advertisement

0.5 sec
0.1 sec.
Indoor
Fan
6 times
blinking
Motor Error
0.5 sec
0.1 sec.
Refrigerant
7 times
blinking
Cycle Error
0.5 sec
0.1 sec.
Other Error
8 times
blinking
0.1
0.5 sec
Indoor Fan Lock Error
sec.
2 times
blinki
ng
0.1
0.5 sec
Indoor Fan Speed Error
sec.
3 times
blinki
ng
0.1
0.5 sec
Discharge Temperature
sec.
2 times
Error
blinki
ng
0.1
0.5 sec
Excessive High Pressure
sec.
3 times
Protection on Cooling
blinki
ng
0.1
0.5 sec
Active
Filter
sec.
2 times
(Permanent Stop)
blinki
ng
0.1
0.5 sec
Active Filter Error
sec.
3 times
blinki
ng
The indoor fan speed is 0 rpm after 56 seconds from starting operation or from the time the fan mode was
changed. > Operation stops. (It releases by sending the operation stop signal from the remote controller.)
[Diagnosis Point]
- Fan motor connector loose/ defective contact.
- Fan motor defective.
- Controller PCB defective.
The indoor fan speed is 1/3 of the target frequency after 56 seconds from starting operation or from the time the
fan mode was changed. > Operation stops. (It releases by sending the operation stop signal from the remote
controller.)
[Diagnosis Point]
- Fan motor connector loose/ defective contact.
- Fan motor defective.
- Controller PCB defective.
The discharge temperature error is activated.
[Diagnosis Poijnt]
- Check if 2 way valve or 3 way valve is left open.
- Heat radiation is blocked (Inlet/Outlet)
- Check if Outdoor Fan is defective (does not rotate).
- Refrigeration cycle defective (Refer to after mentioned "Refrigerant cycle diagnosis").
Excessive high pressure protection on cooling mode has been activated.
> Compressor, Outdoor Fan : OFF (It releases after 3 minute ST)
[Diagnosis Point]
- Heat radiation is blocked (Inlet/Outlet)
- Check if Outdoor Fan is defective (does not rotate).
- Refrigeration cycle defective (Refer to after mentioned "Refrigerant cycle diagnosis").
Error
Output voltage error of Active filter is detected.
[Diagnosis Point]
- Check the wiring connection (Connector is loose/open, Choke coil)
- Controller PCB defective (Refer to after mentioned "Active Filter diagnosis")
Active filter error or instantaneous cut off error is detected.
> Compressor, Outdoor Fan : OFF
[Diagnosis Point]
- Check the wiring connection (Connector is loose/open, Choke coil)
- Controller PCB defective (Refer to after mentioned "Active Filter diagnosis")
<CAUTION> Even if the unit is normal, it may detect error depending on the power supply voltage condition.
> Permanent stop.