T R O U B L E D I A G N O S I S
- 7 9 -
Problems
Causes
Checks
Measures
Remarks
High
Cycle pipe
is
clogged.
Check sequence.
-
Heat up compressor
discharging
Direr
must
be
replaced.
temperature
in
1.
Check
temperature
of condenser
weld
joints
with
touch,
disconnect
the freezer
manually.
the
pipes,
and check the
clogging.
compartment.
Ifitiswarm,itisOK.
Remove the
causes
of
clogging,
If it is
not,
compressor
discharging
weld,
evacuate,
and
recharge
joints might
be
clogged.
the
refrigerant.
2.
Manually
check whether hot line
-
If it's
warm,
it's OK. If it's
not,
pipe
is
warm.
condenser
discharging
line weld
If it is
warm,
it's OK.
joints might
be
clogged.
If it is
not,
condenser outlet weld
Disconnect with
torch,
remove
the
joints might
be
colgged.
causes,
evacuate,
and
recharge
refrigerant.
Leak
at
loop pipe
weld
joint
Check sequence.
Replace
the compressor,
weld,
Drier
must
be
replaced.
(discharge)
in compressor.
1.
Manually
check whether
evacuate,
and
recharge refrigerant.
condenser is
warm,
It is
not
warm
and the frost forms
partly
on
the
evaporator
in the freezer
compartment.
Faulty cooling
fan in the compressor
Check sequence.
-
Replace
if motor does not
operate.
compartment.
1.
Check
cooling
fan
operation.
-
If fan is
disconnected,
check fan
2.
Check that
cooling
fan is
damage
and reassemble it.
disconnected from the
motor.
Refer
to
fan
motor
disassembly
and
assembly
sequence.