Faults - LG GR-B197GVQ Service Manual

Hide thumbs Also See for GR-B197GVQ:
Table of Contents

Advertisement

2. Faults
2-1. Power
2-2.
Compressor
T R O U B L E D I A G N O S I S
- 7 6 -
Problems
Causes
Checks
Measures
Remarks
No power
on
-
Power cord
cut.
-
Check the
voltage
with
tester.
-
Replace
the
components.
outlet.
-
Faulty
connector
insertion.
-
Check
visually.
-
Reconnect the
connecting
parts.
-
Faulty
connection between
plug
-
Check
visually.
-
Reconnect the
connecting
parts.
and
adapter.
Fuse blows
out.
-
Short circuit
by
wrong connection.
-
Check the fuse with
tester
-
Find and
remove
the
cause
of
-
Replace
with rated
-
Low
voltage products
are
or
visually.
problem(ex.
short,
high voltage,
fuse after
confirming
connected
to
high voltage.
-
Check the
input
volt
are
with
tester
low
voltage).
its
specification.
-
Short circuit
by
insects.
(between
power cord and
products).
-
Replace
with rated fuse.
-
Electricity leakage.
-
Check the resistance of power cord
If fuse blowns out
-
High voltage.
with
tester
(if
it is
0Ω,
it is
shorted).
frequently,
confirm
-
Short circuit of
components
the
cause
and
prevent.
(tracking
due
to
moisture and dust
penetration).
Problems
Causes
Checks
Measures
Remarks
Compressor
-
Faulty
PTC.
-
Check the resistance.
-
If resistance is
infinite,
replace
it
does
not
Vlaue:∞ is defective.
with
new one.
operate.
-
If it is not
infinite,
it is normal.
-
Check other
parts.
-
Compressor
is frozen.
-
If compressor
assembly
parts
are
-
During
forced
operation:
normal
(capacitor,
PTC,
OLP),
-
Operates:
Check other
parts.
apply
power
directly
to
the
-
Not
operate:
Replace
the frozen
compressor
to
force
operation.
compressor with
new
one,
weld,
evacuate,
and
recharge refrigerant.
OLP
It
starts
as soon as
it is
?
Refer
to
weld
repair procedures.
contacted.
Auxiliary winding
Main
winding
Power

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents