LG GR-B197GVQ Service Manual page 40

Hide thumbs Also See for GR-B197GVQ:
Table of Contents

Advertisement

1-10.
Temperature compensation
and
temperature
compensation
circuit
1.
Temperature compensation
in freezer and
refrigerator
1) GR-L207ERA,
GR-L247ERA
2) GR-B207ERA,
GR-B247ERA
u
Temperature compensation
table
by adjustment
value
(difference
value
against
current
temperature)
Ex)
If
changing compensation
resistance
at
a
cold
storage
room
(RCR1)
from 10 kΩ
(current resistance)
to
18 kΩ
(modified resistance),
temperature
at
the cold
storage
will increase
by
+1°C
(+1.8 °F).
EXPLANATION FOR MICOM CIRCUIT
-40-
refrigerator
refrigerator
refrigerator
refrigerator
Freezer
Refrigerator
Resistance value
Temperature
Resistance value
Temperature
Remarks
(RCF1)
compensation
(RCR1)
compensation
180 kΩ
+5 °C
[+9 °F]
180 kΩ
+2.5 °C
[+4.5 °F]
56 kΩ
+4
°C
[+7.2 °F]
56 kΩ
+2.0 °C
[+3.6 °F]
Warmer
33 kΩ
+3 °C
[+5.4 °F]
33 kΩ
+1.5 °C
[+2.7 °F]
18 kΩ
+2
°C
[+3.6 °F]
18 kΩ
+1.0 °C
[+1.8 °F]
12 kΩ
+1
°C
[+1.8 °F]
12 kΩ
+0.5 °C
[+0.9 °F]
10 kΩ
0°C[0°F]
10 kΩ
0°C[0°F]
Reference
temperature
8.2 kΩ
-1
°C
[-1.8 °F]
8.2 kΩ
-0.5 °C
[-0.9 °F]
5.6 kΩ
-2
°C
[-3.6 °F]
5.6 kΩ
-1.0 °C
[-1.8 °F]
3.3 kΩ
-3 °C
[-5.4 °F]
3.3 kΩ
-1.5 °C
[-2.7 °F]
2kΩ
-4
°C
[-7.2 °F]
2kΩ
-2.0 °C
[-3.6 °F]
Cooler
470
Ω
-5 °C
[-9 °F]
470
Ω
-2.5 °C
[-4.5 °F]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents