Quick start guide
Double click on the line with your RCU in the
10
Netbiter window. A new window opens.
The RCU is connected to a local network:
Enter the network settings that apply to your net-
work. To obtain the necessary information concer-
ning your network settings, please contact your
network administrator.
The RCU is directly connected to the computer:
Enter the first three values from your computer's IP
address, for example, 10.1.1. The fourth is set to
a value other than the one used in computer's IP
address.
Example:
If the computer has the IP address 10.1.1.1 then set
the RCU address to 10.1.1.X, where X can be set
to any number between 2 and 254 (not 1, as this is
used by the computer in this example).
Complete setting by giving a valid password and
press "Set". The factory-set password is "admin".
Write down the password and keep it in a safe pla-
ce. If the password is lost the RCU must be returned
for reprogramming
Wait a moment and then run a new "scan" in
Netbiter. The RCU should have a new IP address.
Activate the Heat pump for RCU (remember to ac-
11
tivate the service menu)
-
Fighter 360P
-
Fighter 11XX
-
Fighter 12XX
-
Fighter 13XX *
* The heat pump must be restarted after activation.
Otherwise, it can take up to 10 minutes before communica-
tion can start with the RCU.
6
Start the supplied configuration program Netbiter config according to step 8.
Activate in menu 9.1.3
Activate in menu 9.2.15
"
Activate in menu 9.1.3
Start the web browser and enter the RCUs IP address in the
12
address field and press enter. A log in box will now appear.
Both the user name and password are "admin" (unless it
has been changed). If "page cannot be viewed" is shown
go to troubleshooting.
Check that it is the correct heat pump on the overview dia-
13
gram (if you must choose model see troubleshooting)
"Select "Other" in the settings window. Make settings on
14
the following pages:
Module: Gives Information about the location of the
RCU (used in alarms in SMS and e-mail).
E-mail: Settings if the alarm is to be given via e-mail.
Network: Normally does not need to be changed (see
section "Change IP settings" in event of problems).
Modem: Settings for SMS and dial-up connection via
GSM. Refer to the section "Modem" for further infor-
mation.
User: Add and modify information for users. Bear in
mind that the cell phone number must be given with
the country code, for example +46xxxxxxxx.
ModbusTCP: Need not be changed. Only for users of
ModbusTCP.
RCU 11

Hide quick links: