SMS commands – FIGHTER 360P

SMS commands

The RCU can receive incoming SMS commands and send
back a reply. The table below shows the available com-
mands. If an incorrect message is sent to the RCU, it will
reply with a list of the available commands.

SMS commands for interrogating the heat pump

Command
Answer
Parameter
?STATUS
FIGHTER 360P
S-alarm:
Out:
HW:
H-out:
H-ret:
Comp:
Imm:
Mode:
XHW:
Vent:
DI:
?STATUS2
Vent:
Exh:
Eva:
CPR:
IMM:
REG1:
H-out2:
H-ret2:
REG2:
?ALARM
HP
LP
Filter
Sensors
Therm.Co

SMS commands for controlling the heat pump

Command
Parameter
!ALARM
RESET
!XHW
0 / 3 / 6 / 12 / 24
!MODE
W / SA / S / A / EB
!VENT
0 / 1 / N / 2
!REG1
-10 – +10
!REG2
-10 – +10
Example:
To activate Extra hot water for 12 hours send SMS mes-
sage: !XHW 12
To change the operational mode to summer, send SMS
message: !MODE S
Description
Value
On/Off
Heat pump status (contact between RCU and heat pump)
On/Off
Common alarm
nn,n
Outside temperature
nn,n
Hot water temperature
nn,n
Supply temperature
nn,n
Return temperature
On/Off
Compressor data
On/Off
Immersion heater is operational.
W / SA / S / A / EB
Operating mode (Winter, Spring / Autumn, Summar, Auto, Electric Boiler)
0 / 3 / 6 / 12 / 24
Extra hot water function
0 / 1 / N / 2
Fan speed (Off / Speed 1 / Normal / Speed 2)
1 / 2 / 12
RCU digital inputs
nn,n
Extract air temperature
nn,n
Exhaust air temperature
nn,n
Evaporator temperature
nn,n
Compressor sensor temperature
nn,n
Electic element sensor temperature
-10 - +10
Heating curve offset via RCU
nn,n
Heating medium Flow line 2
nn,n
Heating medium Return line 2
-10 - +10
Heating curve offset 2 via RCU
On/Off
High pressure
On/Off
Low pressure
On/Off
Filter
On/Off
Sensors
On/Off
Temperature limiter
Description
Reset alarm
Activation of Extra hot water (3, 6, 12 or 24 hours. 0=Deactivate)
Change operating mode (Winter, Spring / Autumn, Summar, Auto, Electric Boiler)
Change ventilation (Off, Fan mode 1, Normal, Fan mode 2)
Change RCU Heating curve offset (Adjustable between -10 and +10)
Change RCU Heating curve offset 2 (Adjustable between -10 and +10)
RCU 11
SMS commands – FIGHTER 360P
For the RCU to send a reply to an incoming SMS, the num-
ber of the telephone from which the SMS command was
sent must have been registered to a user, or that the num-
ber check for incoming SMS enquiries has been switched
off.
23