Panasonic FX-100-Z Series Instruction Manual

Panasonic FX-100-Z Series Instruction Manual

Digital fiber sensor
Hide thumbs Also See for FX-100-Z Series:

Advertisement

Quick Links

InstructIon Manual
Digital Fiber Sensor
Thank you for purchasing products from Panasonic Electric Works SUNX
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep this manual in a
convenient place for quick reference.
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use prod-
ucts which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
1
cautIons
● This product has been developed / produced for industrial use only.
● Make sure that the power supply is off while wiring.
● If a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the product may get burnt or damaged.
● Short-circuiting the load or incorrect wiring may burn or damage the
product.
● Do not run the wires together with high-voltage lines or power lines
or put them in the same raceway. This can cause malfunction due to
induction.
● Verify that the supply voltage variation is within the rating.
● If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to
an actual ground.
● If noise generating equipment (switching regulator, inverter motor, etc.)
is used in the vicinity of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
● Do not use during the initial transient time (0.5s) after the power sup-
ply is switched on.
● You can extend the cable up to 100m max. with 0.3mm
cable. However, in order to reduce noise, make the wiring as short as
possible.
● Make sure that stress is not applied to the sensor cable joint, e.g. by
forcible bending or pulling.
● Take care that the product is not directly exposed to fluorescent lamp
from a rapid-starter lamp, a high frequency lighting device or sunlight,
etc. as it may affect the sensing performance.
● This product is suitable for indoor use only.
● Avoid dust, dirt, and steam.
● Take care that the product does not come in contact with oil, grease,
organic solvents, such as thinner, etc., strong acid or alkalines.
● This product cannot be used in an environment containing inflam-
mable or explosive gases.
● Never disassemble or modify the product.
● EEPROM is adopted to this product. Teaching is limited to 100,000
times because of the EEPROM's lifetime.
2
Part DEscrIPtIon
1
2
3
5
6
no.
Part
1
Output indicator (orange)
2
Mode key
3
ON key / Set value UP key
4
OFF key / Set value DOWN key
5
Green digital display
FX-100-Z Series
MEUEN-FX100Z V1.0
WARNING
2
or more
4
Description
Lit when output is active.
● Select mode
● Confirm settings
● Select settings in teaching mode
● Increase set value
● Select various other settings
● Select settings in teaching mode
● Decrease set value
● Select various other settings
Threshold value
no.
Part
6
Red digital display
3
MountInG
When using a DIn rail
*
You may break the spring hook if you do not follow the mounting
instructions carefully.
How to mount the amplifier
1. Fit the spring hook on a 35mm DIN rail and
push forward.
2. Slip the front part of the mounting section
over the DIN rail and release.
How to remove the amplifier
1. Push the amplifier forward.
2. Lift up the front part of the amplifier.
When using screws with washers
Use M3 screws with washers to mount the
amplifier.
Do not use a tightening torque of more than 0.5
N•m or you may break the housing.
How to connect the fiber cable
Be sure to fit the attachment to the fibers first before inserting the fibers into
the amplifier. For details, refer to the Instruction Manual enclosed with the
fibers.
1. Snap the fiber lock lever down until it
stops completely.
2. Slowly insert the fiber cables into the
inlets until they stop (see note).
If the fiber cables are not inserted until
they stop, the sensing range reduces.
Since a flexible fiber is easily bent, be
careful when inserting it.
3. Return the fiber lock lever to the original
position.
*
If the cable is a coaxial reflective type fiber, e.g. FD-G4 or FD-
FM2, insert the single-core fiber cable into the beam-emitting
inlet "P" and the multi-core fiber cable into the beam-receiving
inlet "D." If they are inserted in reverse, the sensing perfor-
mance will deteriorate.
1
Description
Incident light intensity
2
1
35mm
1
2
M3 screw
with washers
3
1
Fiber lock
lever
2
Fiber

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic FX-100-Z Series

  • Page 1 FX-100-Z Series MEUEN-FX100Z V1.0 MountInG Thank you for purchasing products from Panasonic Electric Works SUNX Co., Ltd. Please read this Instruction Manual carefully and thoroughly for When using a DIn rail the correct and optimum use of this product. Kindly keep this manual in a convenient place for quick reference.
  • Page 2: Run Mode

    WIrInG run MoDE Digital display ● Use the cable with the connector CN-24A-Cq (optional) when con- necting this product. When you turn ON the power, the product name is indicated in green and ● Tighten the fixing ring of the cable with connector completely by hand the emission frequency is indicated in red.
  • Page 3: Teaching Mode

    Factory set- tEacHInG MoDE Item Description ting Beware that detection may become unstable if too little margin If the incident light intensity is saturated, which makes between the theshold value and incident light intensity is al- sensing impossible or unreliable, you can reduce the emission level.
  • Page 4: Pro Mode

    limit teaching Factory Item Description setting Limit teaching is used to set the threshold value for the object absent condition only, i.e. for a stable incident light condition. When ECO mode is ON, the display turns off af- ECO mode ter 20s in RUN mode.
  • Page 5: External Input

    Threshold follow-up cycle EXtErnal InPut ● When you have selected emission halt for the external input setting 1-second steps from 1 to 60 seconds. and an external signal is received, is displayed in red. 1-minute steps from 1 to 10 minutes. ●...
  • Page 6: Copy Function

    coPY FunctIon QuIcK sEttInG FunctIon Use the copy function to copy settings from 1 master amplifier to 1 slave Simply by selecting a quick setting number, which are listed in the table at amplifier. The models must be identical! the end of this section, you can set: output operation, emission level, timer, The following settings can be copied: threshold value, output operation, and emission frequency.
  • Page 7: Code Setting Function

    coDE sEttInG FunctIon Error InDIcatIon If the follow error codes are displayed, please take appropriate measures. Selecting codes allow you to set: output operation, timer, emission level, emission frequency, ECO, external input, and shift amount. Display Error description Measures The factory setting is Contact our office.
  • Page 8 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 Europe Headquarter: Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany Phone: +49-8024-648-0 US Headquarter: Panasonic Electric Works Corporation of America 629 Central Avenue, New Providence, New Jersey 07974, USA Phone: +1-908-464-3550...

This manual is also suitable for:

Meuen-fx100z

Table of Contents