Code Setting Function; Error Indication; Unit Versions - Panasonic FX-100-Z Series Instruction Manual

Digital fiber sensor
Hide thumbs Also See for FX-100-Z Series:
Table of Contents

Advertisement

13

coDE sEttInG FunctIon

Selecting codes allow you to set: output operation, timer, emission level,
emission frequency, ECO, external input, and shift amount.
The factory setting is
.
RUN mode
Press for 4s, passing the
+
quick setting function
*
During the setting process, press <MODE> for 2s to cancel and
return to RUN mode. After the last digit is set, code settings
take effect!
Code table, modified unit
1st digit
Emission
Output
Timer
amount
operation
(see note)
level
0
0
non
1
ond 10ms
3
D-on
ond 40ms
2
3
ofd 10ms
ofd 40ms
4
5
non
2
6
ond 10ms
L-on
7
ond 40ms
8
ofd 10ms
ofd 40ms
9
1
A
b
c
d
Auto
E
F
Code table, conventional unit
1st digit
Emission
Output
Timer
amount
operation
(see note)
setting
0
0
non
1
ond 10ms
OFF
D-on
2
ond 40ms
3
ofd 10ms
ofd 40ms
4
5
non
ON
6
ond 10ms
L-on
ond 40ms
7
8
ofd 10ms
9
ofd 40ms
*
For differences between the conventional and modified units,
see unIt VErsIons on page 7.
1
2
Automatic
Code setting
Activate, set
digit
Select digit
values
After last digit is set,
code settings take
effect!
2nd digit
3rd digit
Emission
frequency
External
ECO
input
FX-101□-Z FX-102□-Z
0
1
E_oF
1
2
LtcP
2
3
OFF
Ltc-
3
4
Auto
Eco
0
1
1
2
E_of
2
3
LtcP
3
4
ON
Ltc-
0
1
Auto
1
2
Eco
2-Pt
2
3
OFF
Incident light
3
4
intensity test
0
1
2-Pt
ON
Incident light
1
2
intensity test
2
3
3
4
2nd digit
3rd digit
Emission
frequency
External
ECO
input
FX-101□-Z FX-102□-Z
0
1
E_oF
1
2
LtcP
2
3
OFF
Ltc-
3
4
Auto
Eco
0
1
1
2
E_of
2
3
LtcP
3
4
ON
Ltc-
Auto
Eco
14

Error InDIcatIon

If the follow error codes are displayed, please take appropriate measures.
Display
EEPROM writing error
3
4
The load is short-circuited
causing overcurrent.
Communication error
Disconnection, connection
failure, etc.
15

unIt VErsIons

Please note the difference between the modified unit and the conventional
unit: the modified unit has a "P" mark near the beam emitting inlet. The
conventional unit has no "P" mark.
Modified unit
"P" mark
Beam emitting inlet
4th digit
The modified unit has some additional functionality.
Shift
(see note)
● The emission level has 4 possible settings. For the conventional unit,
the emission level can only be turned ON (35%) or OFF.
5%
● For the external input, an incident light intensity test is available.
● For teaching by external input, an additional option is available to turn
10%
ON/OFF the output every 100ms. See Pro MoDE on page 4.
15%
● Due to more functionality, more codes are available. See coDE sEt-
20%
tInG FunctIon on page 7.
25%
30%
35%
40%
45%
50%
4th digit
Shift
(see note)
5%
10%
15%
20%
25%
30%
35%
40%
45%
50%
7
Error description
Contact our office.
Turn off the power, then check the load.
Check the wiring before using the setting
copy function.
Measures