Download Print this page

Panasonic FX-100 Series Instruction Manual page 3

Digital fiber sensor

Advertisement

<External input setting mode>
<Threshold value follow-up cycle setting mode>
(Under 60 sec.)
(OFF)
<GETA function setting mode>
(SET)
(OFF)
(2,000)
<ECO setting mode>
(OFF)
(ON)
<Inverting digital display setting mode>
(OFF)
<Threshold value margin setting mode>
(OFF)
(Green blinks)
Alert output of external input teaching does not
operate unless any of "
set at the external input setting mode.
<Setting copy mode>
(NO)
(YES)
(READY)
<Reset mode>
(NO)
(YES)
<RUN mode>
Setting item
Factory setting
Shift amount can be selected from 0 to 80% in the limit teaching.
Shift setting mode
Select 0% when it is desired to set the present incident light intensity as a
threshold value.
External input can be selected from emission halt, limit teaching [+], limit
teaching [-], full-auto teaching, ECO (Note 1), 2-point teaching or emission
amount test.
External input
When setting the incident light intensity test "
setting mode
every 100ms when the rate of incident light intensity and threshold value is less
than half of the set shift amount (for example, when the rate of incident light inten-
sity and threshold value is within ±10% for 20% of shift amount) at external input.
Threshold value-
Threshold value set at the limit teaching, full-auto teaching or 2-point teach-
storing setting mode
ing by external input is stored. When selecting Auto in the emission amount
(Note 2)
setting mode, the set emission amount level is also stored.
When incident light intensity exceeds threshold value, this mode can change the
Threshold value
threshold value with each set cycle depending on variations of the incident light in-
follow-up cycle setting
tensity. The follow-up shift amount is same as the one set in the shift setting mode.
mode (Note 3)
However, the threshold value is not stored.
Variations can be reduced by correcting the present incident light intensity in
each amplifier to a target value. Target value to offset incident light intensity
GETA function setting
can be selected from 0 to 2,000 by 100 unit each.
mode (Note 4, 5)
For example, if the target value is set to 2,000 when the incident light inten-
sity is 1,500, the incident light intensity becomes 2,000.
It is possible to light up / turn off the digital display. When ECO setting mode
ECO setting mode
is ON, the display turns off in approx. 20 sec. in RUN mode. To light up the
display again, press any key for 2 sec. or more.
Inverting digital
Digital display can be inverted.
display setting mode
Margin for threshold value to the present incident light intensity can be checked.
When there is no margin, it is possible to make the digital display blink.
"
"
": : Red blinks.
Threshold value
"
"
margin setting mode
"
The settings of the master side amplifier can be copied to the slave side
Setting copy mode
amplifier. For details, refer to "
Reset mode
Returns to default settings (factory settings).
Notes: 1) When ECO is selected at the external input setting mode, key operation on the main body is invalid during
external input.
2) This mode is not indicated unless any of "
setting mode.
3) If the incident light intensity becomes "300" or less, the follow-up operation stops.
In that condition, threshold value [digital display (green)] blinks.
This function can be used when thru-beam type or retroreflective type fiber is applied to this product. If reflec-
tive type fiber is applied, the function cannot be used depending on use conditions.
4) If pressing MODE key in RUN mode when GETA function is used, the incident light intensity before setting
GETA function is displayed on the red digital display for approx. 2 sec.
5) When GETA function is used in saturation of incident light intensity (4,000 or more), "
the red digital display. Correction value is up to 4,000.)
6) This mode does not operate unless any of "
mode.
(1 to 9 min. or less)
(10 to 60 min. or less)
: Select a target value from 0 to 2,000
(100 unit each) to correct the incident
light intensity.
(ON)
(Red blinks)
(Red and Green blink)
", "
" or "
" is
Alert output of external
input teaching
Turn the power off when copying the settings.
: Cancellation is possible when
pressed for 2 sec. or more.
Description
", output turns ON / OFF
" : Green blinks.
: Red and Green blink.
" : When conducting limit teaching or 2-point teaching by external input,
in case the rate of reference incident light intensity and threshold
value after teaching is 200% or more, or in case it is less than half of
the shift amount, output turns ON / OFF every 100ms. (Note 6)
SETTING COPY FUNCTION."
", "
", "
" or "
" is set at the external input
", "
" or "
" is set at the external input setting
9
EXTERNAL INPUT SETTING
● When selecting emission halt in the external input setting mode and receiving the
signal externally, "
● When selecting ECO in the external input setting mode, key operation on the main
body is invalid during external input.
● When selecting 2-point teaching in the external input setting mode, "
cated on the green digital display after inputting the first point.
● For the setting of external input, refer to "
<Time chart when setting external input>
External input signal
Emisson halt
(Note 1)
Limit
teaching
Full-auto
teaching
(Note 4)
ECO mode
2-level
teaching
Notes: 1) Output may turn ON / OFF when emission is halted or is released depending on setting of threshold value.
2) When emission starts, output operation will be undetermined only during the response time.
If the output signal is received by something such as a PLC, set the timer to a value of 20ms amplifier response time or greater.
Example: For the FX-101□ with emission frequency 0 (response time 250µs or less)
Timer period: 20ms + 0.25ms (250µs) = 20.25ms
3) After teaching is complete, output operation will be undetermined only during the response time. If the output
signal is received by something such as a PLC, set the timer to the amplifier response time or greater.
The threshold value will be set based on the incident light intensity at the instant when teaching is verified.
4) Move the sensing object past once during the time that the external input signal is being input.
5) After teaching is complete, output operation will be undetermined only during the response time. If the output
signal is received by something such as a PLC, set the timer to the amplifier response time or greater.
<Alert output of external input teaching>
● When conducting limit teaching or 2-point teaching by external input, if the alert output of
external input teaching "
turns ON / OFF every 100ms in case the rate of reference incident light intensity and thresh-
old value after teaching is 200% or more, or in case it is less than half of the shift amount.
For the setting method, refer to <Threshold value margin setting mode> under "
External input signal
Limit teaching
Output operation
when selecting
alert output of
external input
teaching
"
"
2-level teaching
Output operation
when selecting
alert output
of external
input teaching
"
"
Notes: 1) In case the margin is no good, output turns ON / OFF every 100ms during the time that the external input
signal is being input after teaching.
2) In case the margin is no good, output turns ON / OFF every 100ms during the time that the external input
signal is being input after the second teaching.
10
SETTING COPY FUNCTION
● This can copy the settings of the master side amplifier to the slave side amplifier.
● Be sure to use the setting copy function between the identical models. This func-
tion cannot be used between different models.
● Only one sensor can be connected on slave side with a master side sensor for the setting copy function.
● Threshold value, output operation setting, timer operation setting, timer setting, emission
amount setting, shift setting, external input setting, threshold value-storing setting, ECO
setting, inverting digital display setting, and threshold value margin setting can be copied.
Setting procedures
1. Set the setting copy mode of the master side amplifier to "Copy sending ON," and press
MODE key so that "
ready state. For the setting method, refer to <Setting copy mode> in "
2. Turn off the master side amplifier.
3. Connect the master side amplifier with the slave side amplifier as shown below.
Master side amplifier
Slave side amplifier
" is indicated on
" is indicated on the red digital display.
PRO MODE."
25ms or more
20ms or more
20ms
20ms
20ms
(Note 2)
20ms
20ms
(Note 3)
Sampling in
Teaching in progress
progress
20ms
20ms
20ms
(Note 5)
20ms
20ms
20ms
(Note 2)
First point
Second point
20ms
20ms
" is set in the threshold value margin setting mode, output
25ms or more
20ms or more
20ms
20ms
100ms
100ms
100ms
(Note 1)
First point
Second point
20ms
20ms
100ms
" is shown on the digital display and the sensor is in copy
Color code of cable with connector
(Brown)+V
(Black)Input
Power supply
(White)External input
(Blue)0V
(Brown)+V
(Black)Input
(White)External input
(Blue)0V
" is indi-
NPN output
High
type: Low
Low NPN output
type: High
Emission halt
20ms
Emission
Teaching in progress
Normal operation
20ms
Normal operation
ECO in progress
20ms
Normal operation
Teaching in progress
Normal operation
PRO MODE."
NPN output
High
type: Low
NPN output
Low
type: High
Teaching in progress
Normal operation
100ms
ON
OFF
(Note 1)
Teaching in progress
Normal operation
100ms
ON
OFF
(Note 2)
PRO MODE."

Advertisement

loading

This manual is also suitable for:

Mje-fx100cFx-101Fx-102Fx-101-cc2Fx-101pFx-101p-cc2 ... Show all