Permanent light function
l
If a mains switch is installed in
the mains supply lead, the light is
capable of the following functions
in addition to the simple "ON/OFF"
function:
Sensor operation
1) Switch light "ON"
(when light is"OFF"):
Turn switch "OFF" and "ON" once.
Light stays "ON" for the period
selected.
2) Switch light "OFF"
(when light is "ON"):
Turn switch "OFF" and "ON" once.
The light goes out or switches to
sensor mode.
Functions
,
,
g h i
Once installed, the sensor can be
put into operation. Control dials
are provided on the sensor unit for
selecting time, twilight and pro-
gramme settings. After pressing the
Switch-off delay
(time setting) g
(factory setting: 5 sec.)
5 sec. – 15 min.
Manual override
1) Activate manual override:
Turn switch "OFF" and "ON" once.
The light is set to stay on for 4 hours
(red LED lights up behind lens).
Then it returns automatically to sen-
sor mode (red LED off).
2) Deactivate manual override:
Switch "OFF" and "ON" once. The
light goes out or switches to sensor
mode.
Important:
The switch should be actuated in
rapid succession (in the 0.5 –1 sec.
range).
engagement lug f with a flat-bladed
screwdriver, the sensor unit can be
removed for ease of setting. The
IS NM 360 and connected light
switch to permanent light "ON".
Light "ON" time can be adjusted
continuously from 5 sec. to 15 min.
Control dial set to – = shortest time
(5 sec.)
Control dial set to + = longest time
(15 min.)
When setting the detection zone, it is
recommended to select the shortest
time –.
14
Functions
,
,
g h i
Twilight setting
(response threshold)
h (factory setting:
daylight operation
2000 lux)
2 - 2000 lux
Programme setting
(factory setting:
i
programme 1)
2 - 2000 lux
* Note on comfort programme
-
4
midnight
The sensor contains no integrated
clock, the middle of the night is
determined by the length of the dark
phases. To work perfectly, therefore,
it is important for the connected
load to be permanently supplied
with power during this period. Dur-
ing the first night (calibration phase)
basic brightness remains activated
The sensor's response threshold can
be infinitely varied from 2 – 2000 lux.
Control dial set to
= daylight opera-
tion at approx. 2000 lux.
Control dial set to
= night-time
operation at approx. 2 lux.
To adjust the detection zone in day-
light, the control dial must be set to
(daylight operation).
Standard programme
1
Sensor "ON" only in response to
movement as from the selected
light threshold setting
Comfort programme
- evening
2
Sensor "ON" for approx. 2 hours as
from the selected twilight setting,
followed by normal sensor mode (4)
Comfort programme
-
3
evening/morning
Sensor "ON" for approx. 2 hours as
from the selected twilight setting,
followed by normal sensor mode
and, once again, approx. 2 hours of
constant light as from the twilight
setting at dawn
Comfort programme
- midnight*
4
Sensor "ON" to the middle of the
night* as from the selected twilight
setting, followed by standard
programme
throughout the night. Values remain
saved even in the event of mains
power failure. We recommend not
to interrupt the power supply in
programme
. As the values are
4
determined over several nights, the
connected load should, in the event
of any fault, be observed over several
nights to ascertain whether the switch-
off time moves towards midnight.