Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control installation, servicing and user instructions (48 pages)
Gas combination boiler for central heating and hot water production, wall mounted, copper heat exchanger, fan assisted, room sealed, electronic flame ignition and control installation, service and user instructions (52 pages)
Copper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (48 pages)
Coper wall-mounted combination, gas fired boiler for central heating and domestic hot water production, fan assisted, room sealed compartment, electronic flame ignition and control (44 pages)
Wall mounted, room sealed, fan assisted, gas combination boiler (33 pages)
Summary of Contents for Ferroli i29
Page 1
/ i29 EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE “i25” GC n° 47-267-64 “i29” GC n° 47-267-65...
Page 2
Dear Customer, fig. 2 - Turning the boiler off i25 / i29 is a high-efficiency sealed chamber condensing heat generator for heating and hot water production using natural gas or LPG, and equipped with a microprocessor con- When the boiler is switched off, the electronic board is still powered. Domestic hot water trol system.
Page 3
/ i29 Room temperature adjustment (with optional room thermostat) Advice for transport and handling Using the room thermostat, set the temperature required in the rooms. If the room ther- For lifting and transporting always take suitable safety precautions: keep your back...
Page 4
WRAS. The fitting of a DHW expansion vessel is also recommend- Water treatment If treatment of the water is necessary, Ferroli recommends the exclusive use of specific products such as Fernox or Sentinel to be applied in compliance with the producer's in- structions.
Page 5
Only a Ferroli flue system (with respective accessories) must be used with this unit, as required by BS 5440 and CE standards. cod. 3541I730 - Rev. 02 - 11/2016...
Page 6
/ i29 Other coaxial connections Connection with separate pipes fig. 13 - Examples of connection with coaxial pipes ( = Air / = Fumes) Table. 2 - Typology fig. 15 - Examples of connection with separate pipes ( = Air /...
Page 7
Connection to multiple flues or single flues with natural draught To connect the i25 / i29 boiler to a multiple flue or a single flue with natural draught, the flue or chimney must be expressly designed by professionally qualified technical person- Losses in m nel in conformity with the current standards and regulations.
Page 8
/ i29 Condensate drain 4. SERVICE AND MAINTENANCE The condensate should be run inside as far as is practicably possible. For that purpose, use a pipe of at 4.1 Adjustments least 22 mm diameter and a trap with flexible connection supplied with the unit to facilitate connection Gas conversion of the condensate drain pipe.
Page 9
/ i29 Adjustment of pressure at the burner Competence to carry out the check of combustion performance Since this unit has flame modulation, there are two fixed pressure values: the minimum and max- PLEASE NOTE: BS 6798: 2009 Specification for installation and maintenance of imum, which must be those given in the technical data table according to the type of gas.
Page 10
/ i29 If the combustion reading is greater than the acceptable value AND the integrity of the complete 5. TECHNICAL DATA AND CHARACTERISTICS flue system and combustion circuit seals have been verified and the inlet gas pressure (and gas rate) have been verified, proceed as in section Setting the Air/Gas Ratio valve.
Page 11
/ i29 5.2 General view and main components fig. 25 - Top view 54 51 fig. 26 - Bottom view fig. 28 - General view fig. 27 - Side view cod. 3541I730 - Rev. 02 - 11/2016...
Page 21
GAS BOILER SYSTEM COMMISSIONING CHECKLIST MODENA 38C HE This Commissioning Checklist is to be completed in full by the competent person who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference. CONTROLS Optimum start control Fitted...
Page 22
SERVICE RECORD MODENA 38C HE It is that your heating system is serviced and that the appropriate Service Interval Record is completed. Service Provider SERVICE 01 SERVICE 02 ² % ² % ² % ² % SERVICE 03 SERVICE 04 ²...
Page 24
MODENA 38C HE Before contacting Ferroli please have available the completed BENCHMARK document (located in the back of this manual), boiler serial number and model detail. For Technical assistance during the installation, call our Technical Helpline on 0843 479 0479.