Appendix G:
Important Information About LSR4300 Firmware
When LSR4300 Studio Monitors are connected together in a network, all speakers and subwoofers should have
the same version of finnware installed. LSR4300 Studio Monitors produced prior to September 2006 have
Finnware version 1.1 installed. LSR4300 Studio Monitors produced after September 2006 and LSR4312SP
Subwoofers have finnware version 2.0 or later installed. If your speakers have dissimilar versions of finnware,
you can download the latest version offinnware at www.jblproservice.com.The finnware flahser application
includes text prompts that will guide you through the proceedure.
To detennine if the finnware in associated LSR4300 speakers require an update, detennine the finnware
version currently installed in each speaker using this
procedure:
• Remove the power cord from the loudspeaker.
• Reconnect the power cord to the loudspeaker.
• Following a brief (2 second) start-up sequence, the front panel display will freeze for
approximately 5 seconds with all button LEOs illuminated and the fi rmware version
displayed on the level
meter.
The firmware version should be read as follows:
• The number of green LEOs to the left of the -15dB mark indicate the 1 's digit of the firmware version.
• The number of yellow LEOs to the right of the -15 dB mark indicate the 1/1 Oths digit of the firmware version
.
• For example. Firmware v1.1 will be displayed as follows:
(Ji D
0 0
0
rffu
0 0 0
[fin
0 0
j1
,D
0
0 0
DID
0 0
0
D
iD
0
0 0 0
f )
green~
• Firmware v2 .0 will be displayed as follows:
"
'°0 0
0 0
rf,tJ
0 0 0
o1u
0 0
j1
,D
0
0 0
Or
b
0
0
0
D
iD
0
0 0 0
r )
green~
If your Studio Monitors have differing firmware versions, download the latest version from JBL and update all
speakers in the
system.
Before
proceeding,
read the READ-ME file associated with the finnware file. Copy the
finnware files to a Macintosh computer with OS 10.3 operating system (or later) or a PC with Windows 2000,
XP operating system (or later) . Using a USB
cable,
connect
the
computer to the speaker to be
updated.
Click on
the Flash Update application for Mac or Windows and follow the
prompts.
Notes:
• Using LSR4300 speakers with differing fi rmware versions is not harmful to any of the speakers
.
However, some features will not work correctly and system performance may be impaired.
• If after performing a firmware update, an incorrect firmware type has been loaded, ie: if firmware intended for an
LSR4328P has been installed in an LSR4326P, or vice versa
,
upon power up all LEOs of the display will flash, the LEOs
to the left of -15 will be green
.
The LEOs to the
right
of the -15 mark will be red
,
and all of the button LEOs will flash too
.
To resolve this
error,
disconnect and reconnect the power cable from the speaker. Then perform the firmware update
procedure using the correct firmware type.
If you experience any difficulties, go to
www.jblpro.com/lsr
for the latest information related to the firmware.
Or contact:
JBL Customer Service (Monday through Friday)
8:00am - 5:00pmPacific Coast Time In the
U.S.A.
(800) 8JBLPRO (800.852.5776)
www.jblproservice.com