Disassembling Procedure - Sharp AY-XP08CE Service Manual

Split type room air conditioners
Hide thumbs Also See for AY-XP08CE:
Table of Contents

Advertisement

AY-XP08/10/13CE
AE-X08/10BE-C
AE-X13BE
FOR INDOOR UNIT [AY-XP08CE/AY-XP10CE/AY-XP13CE]
CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY SERVICING
1. Open the opne panel, and remove 2 air filters.
2. Remove 4 screws fixing the front panel.
3. Remove the screw fixing the cord clamp.
Note :
During reassembly, install the holder after installing the
front panel. This will make it
easier to assemble the front panel.
4. Close the open panel. Pushing the nail of the front
panel.

DISASSEMBLING PROCEDURE

5. Pull the front panel up.
6. Remove the unit-to-unit wiring from the terminal
7. Remove a screw fixing the control box cover, and
8. Remove 2 screws fixing the 2 ground wires and
Note :
During reassembly, take care direction of the lead wires.
34
board.
remove it.
terminal.

Hide quick links: