Sharp AY-XP08CE Service Manual page 39

Split type room air conditioners
Hide thumbs Also See for AY-XP08CE:
Table of Contents

Advertisement

FOR OUTDOOR UNIT [AE-X08BE-C/X010BE-C/X13BE]
CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY
1. Loose a screw fixing the side cover.
2. Loose the unit to unit cord.
3. Loose a screw fixing the cord clamp.
Right side view
4. Loose 4 screws fixing the top panel.
Left side view
39
Right side view
Front view
5. Loose 6 screws fixing the front panel.
6. Cut 3 nylon bands.
7. Disconnect following connectors and each wire.
Choke coil(two terminal)
Fan motor
Thermistor
Reverse valve (AE-X08BE-C/10BE-C/13BE)
AY-XP08/10/13CE
AE-X08/10BE-C
AE-X13BE
SERVICING
Left side view

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ae-x08be-cAy-xp10ceAe-x10be-cAe-x13beAy-xp13ce

Table of Contents