Configuration Switch Settings
Each model type must be configured for one of several different operating modes,
depending on the machine's requirements. This is done by setting the controller's
configuration dip-switches located on the top panel of the enclosure. There are 10
switches provided, each one can be set to On or Off. The operating functionality
determined by these switches varies depending on the controller's model type.
The following tables define how the configuration dip-switches are used for each
model type.
Model Types: XL200 & XL200H
Switch
#
1
Material stops for each Shear
(cut) operation
2
Output provided for Shear Die
Boost functionality
3
Machine does NOT shift into a
slow speed prior to each shear
(cut) operation
4
Auto-Crop functionality is
DISABLED
5
Material stops for each punch
operation
6
Output provided for Punch Die
Boost functionality
7
Machine does NOT shift into a
slow speed prior to each punch
operation
8
Reserved –Set to Off
9
SVGA Monitor DISABLED
10
Reserved –Set to Off
10
Off
Material does NOT stop for
each shear (cut) operation
Output provided for Shear Up
functionality
Machine DOES shift into a
slow speed prior to each shear
(cut) operation
Auto-Crop functionality is
ENABLED (for machines that
are incapable of performing a
stationary cut)
Material does NOT stop for
each punch operation
Output provided for Punch Up
functionality
Machine DOES shift into a
slow speed prior to each
punch operation
Reserved –Set to Off
SVGA Monitor ENABLED
Reserved –Set to Off
On